© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7-04-49
15
Daily
Preventative Maintenance Checklist
Machine:
Week of:
Operator:
Days
Checks
1
2
3
4
5
6
7
Observe All Safety Warnings!
Beginning of the Day:
1. Inspect the water inlet valve hose connections on the back of
the machine and at the faucets for leaks.
2. Inspect the steam hose connections for leaks (where
applicable).
3. Verify that the insulation is intact on all external wires and
that all connections are secure. If bare wire is evident,
contact a service technician.
4. Check the door interlock before starting operation:
a. Attempt to start the machine with the door open. The
machine should not start with the door open.
b. Close the door without locking it and attempt to start the
machine. The machine should not start with the door
unlocked.
c. Close and lock the door and start a cycle. Attempt to open
the door while the cycle is in progress. The door should
not open.
5. If the washer-extractor is equipped with a premium Wet
Clean module, inspect the water recirculation pipe
connections to make sure that they are tight and do not leak.
Laminate this checklist so that it can be re-used.
To reduce the risk of electrical shock, serious
injury or death, disconnect the electrical power to
the washer-extractor before examining the wiring.
W636
WARNING
(continued)