Diagnostic Test Sequence
Test
Information
Explanation
Unload
End of the Diagnostic Cycle
* The second drain valve will be opened if a second drain valve has been selected in the Configuration menu.
** No number 2 is displayed at the sensor test as this takes only a fraction of a second.
If ++ ++ is displayed at the motor test sequence, then you can Advance (Press START) the test Sequence.
Table 50
Basic Diagnostic Wash Program
Error Messages
• If the computer detects some problem during the Diagnostic
Help Program, a diagnostic error message is generated.
• Check also the Error Log List in the Service Menu.
• Check the error handling and explanation of the error messag-
es.
Basic Diagnostic Wash Program
Sequence
Supply
Inlet
Tem-
pera-
ture
Level
Wash Ac-
tion
Time
R.P.M
.
Top
Front
Top
Front
Top
Front
Step 1 Wash
Wash
B
2=30
seconds
3-4-5
2-3-6-8
104°F
[40°C]
NL
A=12 seconds
R=3 seconds
6 mi-
nutes
W
Drain
Drain
-
-
-
-
-
-
-
30 sec-
onds
D
Step 2 Rinse 1
Rinse 1
-
-
2-5-6
1-2-7
-
NH
A=12 seconds
R=3 seconds
1.5 mi-
nutes
W
Spin
Spin
-
-
-
-
-
-
-
1 minute L
Step 3 Final
Rinse
Rinse 2
C
3=30
seconds
1(+6)
4-7
-
NL
A=12 seconds
R=3 seconds
2 mi-
nutes
W
Spin
Spin
-
-
-
-
-
-
-
4.5 mi-
nutes
H
Slowdown
-
-
-
-
-
-
1 minute -
Tumble
-
-
-
-
-
A=12 seconds
R=3 seconds
30 sec-
onds
W
Table 51
Troubleshooting
©