801683
61
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
• Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
Section 4
Grounding
26. WALL RECEPTACLE POLARITY CHECK
Figure 10
W011GE3A
Neutral
S
ide
Round
Groundin
g
Pron
g
L1
Neutral
Ground
0
V.A.C.
115±12
V.A.C.
115±12
V.A.C.
NOTE: Have a qualified
electrician check polarity of
wall receptacle. If a voltage
reading is measured other
than that illustrated, the
qualified electrician should
correct the problem.
W355
S
E3B
220-240
Volt
s
50/60 Hz
*
0 Volt
s
Power
Cord
220-240
Volt
s
50/60 Hz
*
NOTE: Have a qualified
electrician check
polarity of wall
receptacle. If a voltage
reading is measured
other than that
illustrated, the qualified
electrician should
correct the problem.
*Refer to serial plate for
correct voltage and
hertz.
Summary of Contents for HWFB61QN1102
Page 2: ......