Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To Test Electrical Circuit to Ignition System:
1. Close gas shut-off valve.
2. Remove wire harness disconnect block from the
Holding and Booster Coil. Refer to Figure 20.
3. Plug dryer power cord into wall receptacle, start
the dryer in a heat setting.
4. Set test meter to read AC voltage and apply
meter probes into terminals on dryer harness
that would corespond to terminal “1” and “2” on
the coil. Refer to Figure 20. Meter should
register line voltage in all fabric settings, except
FLUFF which should read “zero” VAC.
5. If meter does not read line voltage in step “4”,
check motor switch, thermostats, fabric switch
or timer.
Figure 20
D267S
SECONDARY
COIL
1
2
3
HOLDING
AND
BOOSTER
COIL
SENSOR
SECONDARY
COIL
HOLDING
COIL
BOOSTER
COIL
IGNITOR
D268S
120 VOLT, 60 HERTZ
ELECTRICAL SUPPLY LINE
WIRING SCHEMATIC