Section 7 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
66. INSTALLING NO. 459P3 KIT
a. Remove Phillips head screw (if present), then
apply thumb pressure to the right side of access
door. Refer to Figure 42. When door opens,
move door to left to disengage from door
supports.
b. Disconnect igniter wires at quick disconnect
blocks. Refer to Figure 48.
c. Remove hex head screw holding burner tube
and igniter in place. Refer to Figure 48.
d. Carefully move burner tube toward rear of
dryer, far enough to permit removal of burner
orifice spud from gas valve.
NOTE: Tab on burner tube may have to be
removed from slot in burner housing to obtain
enough clearance.
e. Turn the burner orifice spud out of gas valve
and install No. 60417 Natural Gas Burner
Orifice Spud (metal stamped #40). Torque new
burner orifice spud to 30 inch-pounds (3.4
N-m).
f. Reinstall burner tube, tighten hex head screw
firmly and reconnect igniter leads.
g. Remove the block-open plug and install No.
58768 Vent Screw. Refer to Figure 48.
h. Install No. 60516 “Valve Converted to Natural
Gas” sticker to top side of gas valve, so it
covers the gas valve part number. Refer to
To reduce the risk of electric shock,
disconnect electrical power to dryer before
servicing the dryer.
WARNING
To reduce the risk of fire or explosion,
reach in through access door opening and
turn the gas line shut-off valve handle to
the closed position,
Figure 48.
WARNING
Figure 48
DR012-SV-1
APPLY NO. 60516
VALVE CONVERTED
STICKER HERE
CLOSED
POSITION
OPEN
POSITION
BURNER
ORIFICE
SPUD
TOP VIEW OF
GAS VALVE
PRESSURE TAP
PIPE PLUG
AIR
SHUTTER
HEX HEAD
SCREW
BURNER
TUBE
IGNITER QUICK
DISCONNECT BLOCKS
SHUT-OFF
VALVE
HANDLE
BLOCK
OPEN
PLUG
BLOCK OPEN