12
M411429
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
2. MOTOR OVERLOAD PROTECTOR CYCLES REPEATEDLY
3. MOTOR RUNS BUT CYLINDER DOES NOT TURN.
4. MOTOR DOES NOT STOP
POSSIBLE CAUSE
TO CORRECT
Incorrect voltage.
• Refer to the Installation Manual (supplied with tumbler)
for electrical requirements.
Clothes load too large.
• Remove part of load.
Clothes cylinder is binding.
• Check cylinder for binding. Refer to Adjustment Section
for cylinder adjustment.
Inadequate wiring.
• Check with an electrician to ensure that wiring is
adequate.
Inadequate make-up air.
• Refer to Installation Manual (supplied with tumbler) for
make-up air requirements.
Poor housekeeping.
• Clean lint accumulation on and around the motor.
Broken, loose, or incorrect wiring.
• Refer to wiring diagram located on back of tumbler or in
literature packet.
POSSIBLE CAUSE
TO CORRECT
Motor drive pulley loose.
• Tighten setscrews.
Sheave loose.
• Tighten setscrews.
Broken or loose belt.
• Replace or adjust belt.
Broken or loose drive chain or sprocket.
• Replace or adjust chain or sprocket.
Cylinder is binding.
• Check cylinder for binding. Refer to Adjustment Section
for proper cylinder adjustment.
POSSIBLE CAUSE
TO CORRECT
Inoperative door switch or switch is out-of-
adjustment.
• Test switch and replace if inoperative. Refer to
Adjustment Section for proper switch adjustment.
Non-Metered Models: Inoperative timer or relay.
• Test timer and relay and replace if inoperative.
Metered Models: Inoperative accumulator.
• Test accumulator and replace if inoperative.
Incorrect wiring.
• Refer to wiring diagram located on back of tumbler or in
literature packet.