80
M413438
Section 6 Adjustments
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
97. CYLINDER DOOR STRIKE
Door strike must be adjusted so it has sufficient
tension to hold loading door closed against the
force of a tumbling load. Door strike is properly
adjusted when 8-15 pounds (17.6-33 kg) of pull is
required to open door.
To adjust door strike, open door, loosen acorn nut
and turn door strike screw in or out as required.
Retighten acorn nut. Refer to Figure 51.
Figure 51
T048IE1A
DOOR
STRIKE
DOOR
LATCH
ACORN
NUT