![Alliance Laundry Systems DCB30CE Service Manual Download Page 57](http://html1.mh-extra.com/html/alliance-laundry-systems/dcb30ce/dcb30ce_service-manual_2901297057.webp)
M413438
59
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
74. DOOR HINGE
a. Open loading door.
b. While supporting door, remove upper hinge
shoulder bolt holding door to hinge bracket.
c. Remove door from hinge bracket.
NOTE: Nylon washer must be in place on lower pin
when reinstalling loading door.
d. Remove nuts and screws holding hinge to door
frame. Refer to Figure 33.
75. DOOR HANDLE
a. Open loading door.
b. Remove screws holding door handle to door
frame. Refer to Figure 31.
76. FRONT PANEL
a. Remove control panel.
b. Unlock, open and remove lint panel. Set aside
to prevent damage.
c. Open loading door, support door and remove
upper hinge bolt holding door to hinge bracket.
Refer to Figure 32.
NOTE: Nylon washer must be in place on lower
hinge pin when reinstalling door.
d. Remove door from bracket.
e. Support front panel and remove screws (and
three speed nuts — newer models only) holding
front panel to tumbler cabinet. Refer to
Figure 34.
f. Remove front panel.
NOTE: When removing front panel, lower panel
slightly to make sure door switch rod clears hole in
cabinet.
Figure 32
Figure 33
T028SE1A
HINGE
BRACKET
HINGE
BOLT
LOADING
DOOR
ASSEMBLY
T029SE1A
LOADING
DOOR
HINGE
HINGE
ATTACHING
SCREWS