background image

DRY616R_SVG

"d 1"

Control Software Version Number Test

Service Door Opening Test

"d 9"

Coin Vault Opening Test

"d 10"

Coin Drop #1 Input Test

"d 11"

Coin Drop #2 Input Test

Press the 
START keypad.

Press the LOW TEMP or 
the DELICATES keypad 
to scroll through the 
Diagnostic Test options.

"dIAg"

Diagnostic Tests

"d 12"

Start Pulse Test

"d 13"

Dryer-on Temperature Test

"d 14"

Thermistor Temperature Test

"d 30"

Machine Configuration #2 Display Test

"d 31"

To enter a test, press 
the START keypad. 
To exit a test, press 
the MED TEMP
keypad.

"d 29"

Machine Configuration #1 Display Test

"d 2"

Input/Output Board Software Number

"d 8"

Vend Header Present Status Test

"d 32"

"d 33"

"d 15"

Door Switch Input Test

"d 19"

Machine Configuration #3 Display Test

Machine Configuration #4 Display Test

Machine Configuration #5 Display Test

Figure 8

Testing Machine and Electronic Control Functions

©

 Copyright, Alliance Laundry Systems LLC -

 DO NOT COPY or TRANSMIT

  34

  Part No. D516167ENR4

Summary of Contents for BDEBCAGS173TN01

Page 1: ...del Identification Original Instructions Keep These Instructions for Future Reference CAUTION Read the instructions before using the machine If this machine changes ownership this manual must accompany machine Part No D516167ENR4 January 2019 ...

Page 2: ......

Page 3: ...anual are not meant to cover all possi ble conditions and situations that may occur It must be understood that common sense caution and care fulness are factors which cannot be built into these washers These factors MUST BE supplied by the per son s installing maintaining or operating the unit Always contact the distributor service agent or the manufacturer about any problems or conditions you do ...

Page 4: ... Partial Vend Mode 12 Additional Vend Mode 12 Start Mode 12 Entering Coins 12 Entering Cards 12 Changing Active Cycles 12 Opening the Dryer Door 12 Signals 13 Special Features 14 Programming Control 14 Collecting Audit Information 14 Testing Machine and Control Functions 14 Rapid Advance Feature 14 Communications Mode 14 Coin Drop 14 Copyright 2019 Alliance Laundry Systems LLC All rights reserved ...

Page 5: ... Time Seconds 2toS 24 Coin 1 Value dEn1 24 Coin 2 Value dEn2 24 Start Pulse Value PLSE 25 Default Cycle dCyC 25 How to Read Default Cycle Value Table 25 Card Reader Display Control CArd 26 Audio Signal AUd 26 How to Program the Audio Signal 26 Global Error Programming Err 26 Cool Down Time Cd 26 Time Display Format t dF 27 High Temperature Hi t 27 Medium Temperature Nd t 28 Low Temperature Lo t 28...

Page 6: ...35 Door Switch Input Test 36 Thermistor Temperature Test 36 Machine Configuration Display 1 Test 36 Machine Configuration Display 2 Test 36 Machine Configuration Display 3 Test 36 Machine Configuration Display 4 Test 37 Machine Configuration Display 5 Test 37 Factory Test Cycle 37 To Enter Factory Test Cycle 37 To Exit Factory Test Cycle 37 Error Codes 39 Rapid Advance Feature 42 How to Enter Rapi...

Page 7: ...CW303UN01 SDEBXAGS403UW01 SSGBXAGS113TW01 BDGBLBGS303AW01 HDGBXRGS113CW01 NDEBLBGS403UT01 SDEBXAGS433AW01 SSGBXAGS303EW01 BDGBLBGW543NW01 HDGBYAGS113CW01 NDEBXAGS303UW01 SDEBXAGS543DW01 SSGBXAGW113FW01 BDGBXAGS113TW01 HDGBYRGS113CW01 NDEBXAGS403UW01 SDEBXRGS153TW01 SSGBXAGW113TW01 BDGBXAGS303AW01 HDGBYRGS113TW01 NDEBXRGS303NW22 SDEBXRGS173TW01 SSGBXAGW303AW01 BDGBXAGW303AW01 HSEBCAGW173TW01 NDGBLB...

Page 8: ...PDEBXRGS173CW02 SDGBXAGS123DW01 STGBXASP304AW01 GDGBXABW303UN01 HTEBXASP134FW01 PDEBXRGS173TG02 SDGBXAGS543DW01 STGBXASP304AW12 HDEBCAGS173TW01 HTEBXASP285CW01 PDEBXRGS173TW02 SDGBXRGS113FW01 STGBXASP304NW22 HDEBCRGS173TW01 HTEBXASP295CW01 PDEBXRGS433AG02 SDGBXRGS113TQ01 STGBXASP304ZW01 HDEBERGS153CW01 HTEBXASP304NW22 PDGBCRGS113TG02 SDGBXRGS113TW01 STGBXASP544DW01 HDEBERGS173CW01 HTEBXASP544DW01 ...

Page 9: ...are referred to throughout the instructions Display This term refers to the window area of the control that displays words and values LED Light Emitting Diode This term refers to the lights next to the keypads and status words of the control FEC Front End Control I O Board Input Output Board OPL On Premises Laundry Power Failure Recovery If a cycle is in progress and the power fails the cycle stat...

Page 10: ...the dryer door is closed Both the START pad and the SELECT CYCLE pads are used in various combinations for programming cycles retrieving audit information running diagnostic tests and other operations Dur ing an active cycle card reader equipped machines only the START pad may be pressed with a card inserted to add time to a cycle DRYING HIGH TEMP HIGH TEMP DELICATES LOW TEMP COOL DOWN START DRY63...

Page 11: ...LED is lit to indicate that the heat portion of the cycle is currently in operation The DRYING LED goes off when the COOL DOWN portion of the cycle begins COOL DOWN LED The COOL DOWN LED is lit whenever the COOL DOWN por tion of a heated cycle is active The COOL DOWN LED will shut off when a cycle ends or more time is added pushing the cy cle back into the heated portion of a cycle Four 7 Segment ...

Page 12: ... card is entered or a start pulse is received When any of the above happens the display will revert back to the Ready Mode Entering Coins Coins are entered to satisfy the programmed vend price for a se lected cycle Coins may be entered before selecting a cycle or during an active cycle When coins are entered during an active cycle the time remaining is increased by the amount program med by the ow...

Page 13: ...rd Insertion Signal The signal will sound for a quarter of a second each time a coin or start pulse is received or a card is entered 3 Serial Command Signal This signal will sound for a quarter of a second each time the control receives a valid serial vend command 4 Signal for Start This signal will sound one second on and one second off for 10 seconds when START LED is flashing after vend has bee...

Page 14: ...c tests refer to Testing Machine and Electronic Control Functions Rapid Advance Feature This feature allows the user to quickly advance through an active dryer cycle or advance into a cycle from the Ready Mode This feature is useful when tests must be performed immediately on a dryer currently in an active cycle In this case the user can quick ly advance through the cycle to the Ready Mode At this...

Page 15: ...WASH INSERT COIN CARD 505617 DRY578R_SVG 1 3 2 1 OPERATING INSTRUCTIONS Select Wash Temperature HOT WARM COLD Select Fabric Type NORMAL PERM PRESS DELICATE Load Supply Dispenser See Instructions Below Load Clothes Insert Coin s Card To Start Washer Close Door and Push Start 1 2 3 4 5 6 Open Dispenser Door Load Supplies in Proper Compartment as Indicated Close Dispenser Door 1 2 3 Detergent Liquid ...

Page 16: ...the MED TEMP keypad with the other hand 5 The display will show rAPd 6 Press the LOW TEMP or the DELICATES keypad to scroll through the options until the desired option appears in the display 7 Press the START enter keypad to enter the displayed mode 8 To exit press the MED TEMP keypad The control will revert back to Ready Mode By default Manual Programming is turned on The manual features availab...

Page 17: ...T keypad Press the START keypad to reset control Press the START keypad to enter Diagnostic Tests Refer to Diagnostic Tests flowchart TMB1587R_SVG Press the START enter keypad to read audit Press the START enter keypad to read audit Press the START enter keypad to read audit Press the START enter keypad to read audit toC1 Total coin 1 top offs toPL Total start pulse card reader top offs toC2 Total...

Page 18: ... what will show in the display when that option is selected Programmable Options Available Option Number Option Display Description Default Value Value Range 1 AtS Heat Cycle Vend Price 200 0 65535 2 CyCL Heat Cycle Time Mi nutes 45 1 99 3 CyCS Heat Cycle Time Sec onds 0 0 59 4 C1to Coin 1 Top Off Time Minutes 5 0 99 5 1toS Coin 1 Top Off Time Seconds 38 0 59 6 C2to Coin 2 Top Off Time Minutes 22 ...

Page 19: ...60 F 38 72 C b Md t Medium Temperature 155 F 68 C no heat 100 160 F 38 72 C c Lo t Low Temperature 145 F 62 C no heat 100 160 F 38 72 C d dELt Delicates Temperature 115 F 46 C no heat 100 160 F 38 72 C 21 t FC Temperature Fahren heit Celsius FAHr FAHr CELS 22 HtdP Heat Indicator Decimal Point On Off oFF on oFF 23 oPL OPL Mode Enable On Off oFF on oFF Programming Control Copyright Alliance Laundry ...

Page 20: ...Figure 4 Programming Control Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 20 Part No D516167ENR4 ...

Page 21: ...Figure 5 Programming Control Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 21 Part No D516167ENR4 ...

Page 22: ...n the display Press the START enter key pad 4 Press the LOW TEMP or the DELICATES keypad to increase or decrease the value of the fourth digit NOTE The vend price can be set from 0 to 65 535 The default value is 25 NOTE To go back to the current programmable op tion without changing the value press the MED TEMP keypad 5 Press the LOW TEMP or the DELICATES keypad to increase or decrease the value o...

Page 23: ...es C1to This option allows the owner to set the amount of top off time in minutes for Coin 1 1 Control must be in Manual Mode Refer to Entering the Man ual Mode 2 Press the LOW TEMP or the DELICATES keypad un til Prog appears in the display Press the START enter key pad and AtS will appear in the display 3 Press the LOW TEMP or the DELICATES keypad to scroll through the programmable options until ...

Page 24: ...s The maximum amount of time for a cycle in cluding the top off time is 99 minutes The mini mum amount of time for top off is 10 seconds The minimum amount of time for a cycle is 1 minute NOTE The default for Coin 2 Top Off Time Seconds is 0 6 Press the START enter keypad when the correct number of seconds appears in the display The new value is saved and the next option in the parameter will appe...

Page 25: ...e Start Pulse Value can be set from 1 to 65 535 The default value is 25 NOTE To go back to the current programmable op tion without changing the value press the MED TEMP keypad 6 Press the LOW TEMP or the DELICATES keypad to increase or decrease the value of the active digit and the START enter keypad to enter the value of the digit and ad vance to the next digit 7 Press the START enter keypad wit...

Page 26: ...1 Control must be in Manual Mode Refer to Entering the Man ual Mode 2 Press the LOW TEMP or the DELICATES keypad un til Prog appears in the display Press the START enter key pad and AtS will appear in the display 3 Press the LOW TEMP or the DELICATES keypad to scroll through the programmable options until AUd appears in the display 4 When AUd appears in the display press the START enter keypad A n...

Page 27: ...splay format can be set to NN minutes only or NNSS minutes and seconds The default format is NN 5 Press the LOW TEMP or the DELICATES keypad to change the current status 6 Press the START enter keypad when the desired status ap pears in the display The new value is saved and the next op tion will appear in the display High Temperature Hi t This option allows the owner to set the temperature of the...

Page 28: ...egrees displayed in the display to the desired number of degrees Refer to Table 2 for values NOTE The default value is 160 F 71 C 6 Press the START enter keypad when the correct number of degrees appears in the display The new value is saved and the next option in the parameter will appear in the display Delicates Temperature dELt This option allows the owner to set the temperature of the deli cat...

Page 29: ...ress the LOW TEMP or the DELICATES keypad to change the current status 6 Press the START enter keypad when the desired status ap pears in the display The new value is saved and the next op tion will appear in the display OPL Parameters oPL This option allows the owner to enable or disable the OPL Pa rameters in which no vend price needs to be satisfied to operate the machine 1 Control must be in M...

Page 30: ...o scroll through the various options until the desired option is shown in the display Refer to the Audit Options List Table 3 for an explanation of the audit options available Audit Options List Display Description CyC Total of machine cycles Coi1 Total of coins 1 Coi2 Total of coins 2 PLSE Total of start pulses toC1 Total of coin 1 top offs toC2 Total of coin 2 top offs toPL Total of start pulse ...

Page 31: ...Control must be in Manual Mode Refer to Entering the Man ual Mode 2 Press the LOW TEMP or the DELICATES keypad un til rSEt appears 3 Press the START enter keypad The display will show no Use the LOW TEMP or the DELICATES keypad to change to yEs If START enter keypad is pressed while yEs is selected the control will go to diAg If no is selected no change to programming will be made Manual Reset Cop...

Page 32: ...trol must be in Manual Mode Refer to Entering the Man ual Mode 3 Press the LOW TEMP or the DELICATES keypad un til diAg appears 4 Press the START enter keypad Display will change to d 1 indicating the control software version number test 5 Press the LOW TEMP or the DELICATES keypad to scroll through the diagnostic test options How to Start Tests To start a diagnostic test refer to the quick refere...

Page 33: ...F XXXC SH or oP d 29 Machine Configuration 1 Display Test axxx d 30 Machine Configuration 2 Display Test bxxx d 31 Machine Configuration 3 Display Test Cxxx d 32 Machine Configuration 4 Display Test dxxx d 33 Machine Configuration 5 Display Test exxx Table 4 Testing Machine and Electronic Control Functions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 33 Part No D516167ENR4 ...

Page 34: ...stor Temperature Test d 30 Machine Configuration 2 Display Test d 31 To enter a test press the START keypad To exit a test press the MED TEMP keypad d 29 Machine Configuration 1 Display Test d 2 Input Output Board Software Number d 8 Vend Header Present Status Test d 32 d 33 d 15 Door Switch Input Test d 19 Machine Configuration 3 Display Test Machine Configuration 4 Display Test Machine Configura...

Page 35: ...ing of the test To exit the Coin Vault Opening Test press the MED TEMP keypad The control will return to the testing mode Coin Drop 1 Input Test This option tests coin drop 1 To start test control must be in the Testing Mode Refer to How to Enter Testing Feature at the be ginning of this section To enter press the START enter keypad The display will show C1xx The xx will show the number of coins e...

Page 36: ...s section To enter press the START enter keypad The display will show xxxF or xxxC The F will show Fahrenheit the C will show Cel sius and the xxx will show degrees If control senses a shorted thermistor the display will show SH If the control senses an open thermistor the display will show oP To exit this test press the MED TEMP keypad The control will return to the testing mode Machine Configura...

Page 37: ...lay dr for product type dryer 4 The control will advance through the sequence of test steps whenever the START enter keypad is pressed with the ex ception of the Keypad Test Refer to Table 6 for all tests in the Factory Test Cycle To Exit Factory Test Cycle The test will be exited when the time reaches 00 on the control in Step 10 Otherwise the control must be powered down to end the test Factory ...

Page 38: ...open ther mistor oP will be displayed PUSH Strt 10 10 Minute Test Cycle Determines if dryer can function in a cy cle for 10 minutes LED display will flash one second on and one second off If the door is opened while the START LED is flashing the control will display door until the door is closed While this 10 Minute Test Cycle is running the START pad may be used to decrement the remaining cycle t...

Page 39: ...on failure Re aim external device and try again Ei0A Framing Error Communication error Re aim external de vice and try again Ei0C Time out Exceeded Communication error Re aim external de vice and try again Ei0E Encryption Error Incorrect machine type Before download ing ensure data is for current machine type Ei0F Invalid Wake up or Infra red Disabled Communication failure or infra red is disa ble...

Page 40: ...or network board ALm Break in Alarm Error Service the service door or coin vault switches oFF Break in Alarm Shutdown Error Service the service door or coin vault switches Err Coin Error Invalid coin pulse or inoperative coin sen sor Check coin drop area and remove ob structions If error persists tampering may have occurred Evaluate security proce dures E SH Shorted Thermistor Error Dead short in ...

Page 41: ...and Machine ID chip or try replacing the user control or the Machine ID chip E Co Output Board Communication Communication failure Power down power up and try again If error persists check connection between user control and output board or try replacing the user con trol or the output board E 59 Door Input Acquisition Hardware failure Replace output board E 60 Centrifugal Switch Input Acquisition...

Page 42: ...e cycle time by one minute Pressing and holding the START enter keypad will advance the cycle four minutes for every second the START enter keypad is held down How to Enter Rapid Advance During an Active Cycle 1 Be certain service door is open 2 While pressing and holding the HIGH TEMP keypad with one hand press the MED TEMP keypad with the other hand The display will show rAPd Control may be in a...

Page 43: ...gress when the power fails the cycle status is saved in memory When power recovers the control will deter mine whether to automatically continue the cycle from the point it left off requiring the user to press the START pad to continue the cycle Power Fail Recovery Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 43 Part No D516167ENR4 ...

Page 44: ...cations feature allows the control to communicate with the card reader The control can be program med for a limited number of options and have its data read with out using the keypad Communications Mode Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 44 Part No D516167ENR4 ...