Figure 35
Machine Must Be Hard Wired
CHM2555N_SVG
Figure 36
NOTE: Electrical receptacle must be located so that it
is easily accessible with machine in place. An inter-
mediate shut-off box with a 3 mm gap is required to
meet EN 60335-1, clauses 24.3 and 22.2 or 3.5 mm gap
is required to meet Standard IEC 60335-1, clauses 24.3
and 22.2. Gap is defined as the minimum contact sepa-
ration of each pole in the switch between the “ON” and
“OFF” positions.
IMPORTANT: Where an emergency stop is required by
local ordinances, a disconnect must be installed that is
readily accessible to all users.
NOTE: Installation of models in North America: recom-
mended installation is hard wired without a GFCI. If a
GFCI is mandatory due to local requirements, then the
GFCI must be rated for 30mA or higher.
Single-Phase Connections
For single-phase input, connect L1, L2 and Ground and cap neu-
tral as shown in
.
1.
L1
2.
L2/N
3.
Ground
4.
Neutral (capped)
Figure 37
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
76
Part No. F8619501ENR11