Plug In the Washer
Electrical Requirements
NOTE: Refer to the unit's serial plate for proper voltage
and Hertz the unit is designed to operate on. The serial
plate is located under the lid.
NOTE: The wiring diagram is located in the control
hood.
WARNING
To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and protective earth/ground
connections MUST abide with local electrical codes.
It is the customer’s responsibility to have the wiring,
fuses and circuit breakers installed by a qualified
electrician to make sure adequate electrical power is
available to the washer.
W882
When connecting the washer to electrical power:
• DO NOT overload circuits.
• DO NOT use an extension cord.
• DO NOT use an adapter.
• DO NOT operate other appliances on the same circuit.
WARNING
To reduce the risk of an electric shock or fire, DO
NOT use an extension cord or an adapter to connect
the washer to the electric power source.
W082
110 Volt, 60 Hertz, 9.8 Amp
This washer is designed to be operated on a separate branch, po-
larized, three-wire, earth/ground, 110 Volt, 60 Hertz, single-phase
electrical circuit protected by a 15 ampere fuse, equivalent fuse-
tron or circuit breaker.
The three-prong earth/ground plug on the power cord should be
plugged directly into a polarized three-slot effective earth/ground
receptacle rated 110 Volts AC (alternating current) 15 Amps. Re-
fer to
.
Standard 110 Volt, 60 Hertz 3-Wire Effective Earth/
Ground Circuit
TLW2287N_SVG
6
8
7
2
1
3
5
4
1.
L1
2.
Earth/Ground
3.
Neutral Side
4.
Round Earth/Ground Prong
5.
Neutral
6.
0 V.A.C.
7.
110 ± 12 V.A.C.
8.
110 ± 12 V.A.C.