To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
47. CYLINDER BELT
Refer to Figure 15.
a. Support drive guard cover and remove screws
that hold guard to rear of tumbler. Refer to
Figure 13.
b. Loosen the four jackshaft assembly attaching
c. Rotate the adjusting nuts counterclockwise
(approximately three turns). Refer to Figure 14.
d. Slide jackshaft assembly upwards to loosen the
cylinder belt.
e. Remove cylinder belt.
NOTE: After reinstalling belt, adjust drive belt and
cylinder belt. Install new belts as a set of 3.
Figure 14
T316PE3A
CABINET
HIGH LIMIT
THERMOSTAT
JACKSHAFT
ASSEMBLY
JACKSHAFT
EYE BOLT
ATTACHING
BOLTS
JACKSHAFT
EYE BOLT
ADJUSTING
NUTS
LOAD
READY
THERMOSTAT