background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

3

802749

Installation

Step 1: Position Washer Near Installation 
Area

Move washer as close to the desired area of 
installation as possible.

NOTE: For best performance and to minimize 
vibration or movement, install washer on a solid, 
sturdy and level floor. Some floors may need to be 
reinforced, especially on a second floor or over a 
basement. Do not install the washer on carpeting, 
soft tile, a platform or other weakly supported 
structures.

Step 2: Connect Fill Hoses

Water Supply

Water supply faucets must fit standard 3/4 inch
(19.1 mm) female garden hose couplings. DO NOT 
USE SLIP-ON OR CLAMP-ON CONNECTIONS.

Water supply faucets should be readily accessible to 
permit turning them off when washer is not being 
used.

Recommended cold water temperature is 60

to 80

Fahrenheit (16

o

 to 27

o

 Celsius). Recommended 

maximum hot water temperature is 125° Fahrenheit 
(51° Celsius). Warm water is a mixture of hot and cold 
water. Warm water temperature is dependent upon 
water temperature and pressure of both the hot and 
cold water supply lines.

Water pressure must be a minimum of 20 to a 
maximum of 120 pounds per square inch (138 to 827 
kPa) static pressure measured at the faucet.

NOTE: Water pressure under 20 pounds per 
square inch (138 kPa) will cause an extended fill 
time in the washer and may not properly flush out 
the detergent dispenser.

Turn on the water faucets and flush the lines for 
approximately two minutes to remove any foreign 
material that could clog the screens in the water 
mixing valve.

NOTE: When installing in newly constructed or 
renovated buildings, it is very important to flush 
the lines since build-up may have occurred during 
construction.

Connecting Hoses

Remove the two plain rubber washers and two filter 
screens from the accessories bag. Install them into 
each end of the fill hoses as shown in 

Figure 3

. The 

screen must be facing outward.

Screw hose couplings with the filter screens onto the 
water faucets until they are finger-tight. Then, using a 
pliers, screw approximately 1/4 turn.

Screw hose couplings from other end of hoses onto the 
water mixing valve until they are finger-tight. Then, 
using a pliers, screw approximately 1/4 turn. Refer to 

Figure 4

.

IMPORTANT: Do not cross thread or overtighten 
couplings. This will cause them to leak.

Turn water on and check for leaks. If leaks are found, 
turn off the water, unscrew hoses and reinstall them 
until there are no leaks. 

IMPORTANT: Turn off water supply whenever 
there will be an extended period of non-use.

Under certain conditions, hydrogen gas 
may be produced in a hot water system 
that has not been used for two weeks or 
more. HYDROGEN GAS IS EXPLOSIVE. If 
the hot water system has not been used 
for such a period and before using the 
washer, turn on all hot water faucets and 
let the water flow from each for several 
minutes. This will release any 
accumulated hydrogen gas. THE GAS IS 
FLAMMABLE, DO NOT SMOKE OR USE 
AN OPEN FLAME DURING THIS TIME.

W029

WARNING

To avoid personal injury, recommended 
inlet water temperature should be no 
higher than 125

°

 Fahrenheit (51

°

 Celsius).

W709

WARNING

Summary of Contents for 802749r1

Page 1: ...chine changes ownership this manual must accompany machine www comlaundry com Installation Instructions for Frontload Washers Washer Dimensions 2 Before You Start 2 Installation 3 Installer Checklist Back Cover Date Purchased ________________ Model Number ________________ Serial Number _________________ Part No 802749R1 July 2008 Inside ...

Page 2: ... NOTE If the washer is delivered on a cold day below freezing or is stored in an unheated room or area during the cold months do not attempt to operate it until the washer has had a chance to warm up NOTE Some moisture in the wash drum is normal Water is used during testing at the manufacturer NOTE Install dryer before washer This allows room for attaching exhaust duct FLW2205N Figure 1 FLW2205N 2...

Page 3: ...y two minutes to remove any foreign material that could clog the screens in the water mixing valve NOTE When installing in newly constructed or renovated buildings it is very important to flush the lines since build up may have occurred during construction Connecting Hoses Remove the two plain rubber washers and two filter screens from the accessories bag Install them into each end of the fill hos...

Page 4: ...tion Any hose showing the signs of deterioration listed above should be replaced immediately All hoses should be replaced every five years Step 3 Connect Drain Hose to Drain Receptacle Remove the drain hose from its shipping position on the rear of the washer by unhooking the hose from the retainer clamp and by removing the shipping tape Install the drain hose into the drain receptacle standpipe w...

Page 5: ...vent the drain hose from dislodging from drain receptacle during use Wall Installation For installations of this type the drain hose MUST be secured to one of the fill hoses using the beaded strap from accessories bag Refer to Figure 6 NOTE End of drain hose must be below 24 in 61 cm FLW1959N 1 24 in to 36 in 91 44 cm recommended height 2 Standpipe 2 in 5 08 cm or 1 1 2 in 4 cm 3 Beaded Strap Figu...

Page 6: ...f washer is not level tilt washer to access the front and rear leveling legs Loosen the locknuts and adjust legs by screwing into or out of washer base Make sure that the washer does not rock When washer is level and does not rock tighten locknuts securely against bottom of washer base If these locknuts are not tight washer will move out of position during operation Do not slide washer across floo...

Page 7: ...ront access panel Figure 9 IMPORTANT The shipping brace bolts lockwashers and shock sleeves should be saved and MUST be reinstalled whenever the unit is moved more than four feet Do not lift or transport unit from front or without shipping materials installed Refer to the User s Guide for proper instructions on reinstalling the shipping materials IMPORTANT DO NOT tip washer more than 6 inches 152 ...

Page 8: ...instructions for details on operation A junction box on the rear panel houses a terminal strip which furnishes supply output signals for the supply injection pumps Refer to Figure 12 for the injection interface label Supply Injection System Number of liquid supply connections 1 Detergent and 2 Softener 2 Liquid supply connection size in mm 3 8 9 52 or 1 4 6 35 Wear eye and hand protection when han...

Page 9: ... Amp circuits The washer is designed to be operated on a separate branch polarized three wire effectively grounded 120 Volt 60 Hertz AC alternating current circuit protected by a 15 Amp fuse equivalent fusetron or circuit breaker The three prong grounding plug on the power cord should be plugged directly into a polarized three slot effectively grounded receptacle rated 110 120 Volts AC alternating...

Page 10: ... of the wall receptacle If a voltage reading is measured other than that in Figure 13 the qualified electrician should correct the problem NOTE The wiring diagram is located behind the control panel inside the control cabinet Step 9 Check Installation Refer to Installer Checklist on the back cover of this manual and make sure that washer is installed correctly Run washer through one complete cycle...

Page 11: ......

Page 12: ...nection Plain Washers Hot Valve Connection FLW2054N Connect Drain Hose to Drain Receptacle 3 CHECK FLW1959N FLW1959N Position and Level the Washer 4 CHECK FLW2154N FLW2154N Remove the Shock Sleeves and Shipping Brace 5 CHECK FLW2124N FLW2124N FLW2155N Wipe Out Inside of Washer Drum 6 CHECK FLW2155N Connect External Supplies to Washer 7 CHECK Supply Injection Models Only FLW2162N FLW2162N D254I Plu...

Reviews: