background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Introduction

70444901

4

(Continued)

Gas

Steam/Thermal Oil

Electric

45 

Pound 

Stacked

CTT45L
CTT45N
DRST45G2-BAT45L
DRST45G2-BAT45N
DRST45G2-BTT45D
DRST45G2-BTT45L
DRST45G2-BTT45N
DRST45G2-BUT45L
DRST45G2-BUT45N

HAT45L
HAT45N
HTT45D
HTT45L
HTT45N
HUT45L
HUT45N
IPD45STG2-ITT45N
IPD45STG2-ITT45L

SAT45L
SAT45N
STT45D
STT45L
STT45N
SUT45L
SUT45N

Not Applicable

Not Applicable

50 

Pound

CA050L
CA050N
CT050L
CT050N
CU050L
CU050N
DR55G2-BA050N
DR55G2-BA050L
DR55G2-BT050D
DR55G2-BT050L
DR55G2-BT050N
DR55G2-BU050N

DR55G2-BU050L
HA050L
HA050N
HT050D
HT050L
HT050N
HU050L
HU050N
IPD50G2-IT050N
IPD50G2-IT050L
SA050L
SA050N

ST050D
ST050L
ST050N
SU050L
SU050N
UA050L
UA050N
UT050L
UT050N
UU050L
UU050N

CT050S
CT050T
CU050S
CU050T
DR55S2-BT050T
DR55S2-BT050S
DR55S2-BU050S
DR55S2-BU050T
HT050S
HT050T
HU050S
HU050T

IPD50S2-IT050S
IPD50S2-IT050T
ST050S
ST050T
SU050S
SU050T
UT050S
UT050T
UU050S
UU050T

CT050E
CU050E
DR55E2-BT050E
DR55E2-BU050E
HT050E
HU050E
IPD50E2-IT050E
ST050E
SU050E
UT050E
UU050E

55 

Pound

CA055L
CA055N
CT055L
CT055N
CU055L
CU055N
HA055L
HA055N
HT055D
HT055L

HT055N
HU055L
HU055N
IPD55G2-IT055N
IPD55G2-IT055L
SA055L
SA055N
ST055D
ST055L
ST055N

HU055L
HU055N
SU055L
SU055N
UA055L
UA055N
UT055L
UT055N
UU055L
UU055N

Not Applicable

CT055E
CU055E
HT055E
HU055E
IPD55E2-IT055E
ST055E
SU055E
UT055E
UU055E

75 

Pound

CA075L
CA075N
CT075L
CT075N
CU075L
CU075N
DR80G2-BA075N
DR80G2-BA075L
DR80G2-BT075D
DR80G2-BT075L
DR80G2-BT075N
DR80G2-BU075N
DR80G2-BU075L

HA075L
HA075N
HT075D
HT075L
HT075N
HU075L
HU075N
IPD75G2-IT075L
IPD75G2-IT075N
SA075L
SA075N
ST075D
ST075L

ST075N
STF75L
STF75N
SU075L
SU075N
UA075L
UA075N
UT075L
UT075N
UTF75L
UTF75N
UU075L
UU075N

CT075S
CT075T
CU075S
CU075T
DR80S2-BT075T
DR80S2-BT075S
DR80S2-BU075T
DR80S2-BU075S
HT075S
HT075T
HU075S
HU075T
IPD75S2-IT075T

IPD75S2-IT075S
ST075S
ST075T
SU075S
SU075T
UT075S
UT075T
UU075S
UU075T

CT075E
CU075E
DR80E2-BT075E
DR80E2-BU075E
HT075E
HU075E
IPD75E2-IT075E
ST075E
SU075E
UT075E
UU075E

Models continued on next page.

Summary of Contents for 70444901R3

Page 1: ...y com Tumble Dryer OPL Electronic Control Refer to Page 3 for Model Identification Part No 70444901R3 July 2011 Keep These Instructions for Future Reference If this machine changes ownership this manu...

Page 2: ......

Page 3: ...des of Operation 10 Power up Mode 10 Idle Mode 10 Run Mode 10 Rapid Advance Mode 10 Pause Mode 10 Error Mode 10 Communication Mode 11 Cool Down Mode 11 End of Cycle Mode 11 Extended Tumble Mode 11 Rev...

Page 4: ...Motor Test 32 Damper Motor Test 32 Reverse Motor Test 32 Production Test Cycle 33 To Enter Production Test Cycle 33 To Exit Production Test Cycle 33 Machine Errors 34 PDA Communications Error 34 Open...

Page 5: ...0S IPD30S2 IT030S ST030S SU030S UT030S UU030S CHD30E2 CU030E CHD30E2 CT030E DR30E2 BT030E DR30E2 BU030E HT030E HU030E IPD30E2 IT030E ST030E SU030E UT030E UU030E 30 Pound Stacked CHD30STG2 CAT30L CHD30...

Page 6: ...UT050S UT050T UU050S UU050T CT050E CU050E DR55E2 BT050E DR55E2 BU050E HT050E HU050E IPD50E2 IT050E ST050E SU050E UT050E UU050E 55 Pound CA055L CA055N CT055L CT055N CU055L CU055N HA055L HA055N HT055D...

Page 7: ...120N UA120L UA120N UT120L UT120N UU120L UU120N CT120S CT120T CU120S CU120T DR120S2 BT120T DR120S2 BU120S DR120S2 BU120T DR120S2 BT120S HT120S HT120T HU120S HU120T IPD120S2 IT120S IPD120S2 IT120T ST120...

Page 8: ...ill resume the cycle when the power recovers Communications The control has the ability to communicate with a PDA and a laptop with an IrDA device running the control software Devices such as PDAs and...

Page 9: ...nd of Cycle Audio Enabled 5 seconds End of Cycle External Signal Enabled 5 seconds Clean Lint Screen Reminder Off Display Limit Errors Disabled Manual Diagnostics Enabled Manual Programming Enabled Re...

Page 10: ...anage operation of the tumbler Refer to Figure 1 Figure 2 Figure 3 Figure 4 and Table 1 S Models H Models U Models B C and I Models NOTE The reversing feature is not available on all models TMB1345R F...

Page 11: ...urn to Idle Mode when the control displays the main menu or clear an error message from the display STOP Press to pause a cycle while in Run Mode or abort a cycle if the control is in Pause Mode START...

Page 12: ...g Run Mode Press Stop keypad to stop cycle and enter Pause Mode Control enters Pause Mode if loading or lint door opens Press Start to Rapid Advance Rapid Advance Mode If the Rapid Advance Option is e...

Page 13: ...is opened or Stop keypad is pressed The control will then return to Idle Mode Extended Tumble Mode The Extended Tumble Mode has two portions The Anti Wrinkle Tumble is entered two minutes after the cy...

Page 14: ...e time This time is taken from the machine cycles as they are programmed The Total Remaining Cycle Time begins to count down as soon as the cycle is started Time Dry Cycle In this type of cycle the co...

Page 15: ...ypad to enter the displayed mode 6 To exit press the Back keypad The control will revert back to Idle Mode Manual Programming can only be turned on or off with an external device Refer to the appropri...

Page 16: ...d to scroll through the Audit options Press the Start keypad Press the Start keypad to reset control Press the Start keypad to enter Diagnostic Tests Refer to Diagnostic Tests flowchart TMB1372R Press...

Page 17: ...program 3 Press the Up or Down keypad to change the value of that option 4 Press Start to save the change NOTE Press the Back keypad to leave the option without saving any change 5 After pressing Sta...

Page 18: ...ure Dry Target Moisture CXXS56 Segment 5 Reversing Enable Disable 10 Cool Down CXXCd1 Cool Down Temperature CXXCd2 Cool Down Time CXXCd3 Cool Down Segment Reversing Enable Disable 11 Reversing CXX r1...

Page 19: ...a External Signal End of Cycle 1 0 oFF 1 on b External Signal End Of Cycle Duration seconds 5 1 120 7 Multi Segment Cycles 0 1 Enable 0 Disable 8 Advanced Moisture Dry Options 0 1 Enable 0 Disable 9 E...

Page 20: ...ycle XX Material Type CXXtPt Cycle XX Time Past Target Prog Manual Programming on Enable oFF Disable tinE Time Dry Avto Auto Dry noist Moisture Dry 0 Cotton 1 Blend 2 Bedding 3 Delicate 4 Synthetic 5...

Page 21: ...S23 Segment 2 Temperature CXXS24 Segment 2 Auto Dry Target Level CXXS25 Segment 2 Moisture Dry Target Level CXXS26 Segment 2 Reversing Enable Disable CXXS31 Segment 3 Enable Disable CXXS32 Segment 3 T...

Page 22: ...arget Level CXXS46 Segment 4 Reversing Enable Disable CXXS51 Segment 5 Enable Disable CXXS52 Segment 5 Time CXXS53 Segment 5 Temperature CXXS54 Segment 5 Auto Dry Target Level CXXS55 Segment 5 Moistur...

Page 23: ...versing Enable Disable CXX r1 Cycle Reversing Enable Disable CXX r2 Cycle Reversing Rotate Time CXX r3 Cycle Reversing Stop Time Cd Global Cool Down Cd 1 Cool Down Temperature continued continued cont...

Page 24: ...2 Stop Time rEv 3 Advanced Reversing On off tEnp 1 Global Very Low Temperature tEnp 2 Global Low Temperature tEnp 3 Global Medium Temperature tEnp 4 Global High Temperature To enter a programming opt...

Page 25: ...uration ESig External Signal nvLSEg Multi Segment Cycles on off ndryOP Advanced Moisture Dry Options Enable Disable Error Error Displays Avdio Global Audio Signal To enter a programming option press t...

Page 26: ...7 Daylight Savings on off AIg Auto Ignite Retry diAgEn Manual Diagnostics on off t FC Temperature To enter a programming option press the Start keypad To exit press the BACK keypad continued rtC Real...

Page 27: ...eypad to scroll through various options until the desired option is shown in the display Refer to the Audit Options List Table 2 for an explanation of the audit options available 2 Once the desired op...

Page 28: ...s on the control For an explanation of the Factory Default Settings refer to Default Tumbler Settings How to Enter Manual Reset 1 Control must be in Manual Mode to start Refer to Entering the Manual M...

Page 29: ...on each test read the appropriate description How to Exit Testing Feature Press the Back keypad The display will return to Idle Mode Table 3 Diagnostic Testing Mode Quick Reference Chart Display Diag...

Page 30: ...mit Thermostat Status SL XX Stove High Limit Thermostat 1 Status SL2 XX Stove High Limit Thermostat 2 Status ddiP DIP Switch Status diCnAL ICM Alarm Status diCnrS ICM Reset Test dEALrn External Alarm...

Page 31: ...lint door switch has to be closed or open for at least one second for the control to register the switch as closed or open NOTE Loading door must be closed while testing lint door To exit the Lint Doo...

Page 32: ...the ICM reset will become active If the reset signal is active for a long enough period of time 4 seconds the ICM Lockout input will become active To reset the ICM stop the ICM Reset Test and then sta...

Page 33: ...ermistor Temperature Test This option displays the temperature sensed at the thermistor in 5 F increments To start test control must be in the Testing Mode Refer to How to Enter Testing Feature at the...

Page 34: ...t towards the total machine run time operation To exit Fan Motor Test press the Back keypad The control will return to the testing mode Damper Motor Test This option shows the damper motor running To...

Page 35: ...ontrol will show When all keypads have been pressed the control will advance to next step after a one second delay or Loading Door Test The control will display the status of the loading door if door...

Page 36: ...ight Alarms Menu Shorted Thermistor Error Any time the control senses a temperature greater than 210 4 F during an active cycle the control will enter the Cool Down portion of the cycle display this e...

Page 37: ...he cycle will not start and all user inputs will be ignored If the error does clear the control will go back to its previous mode of operation When this error occurs the Airflow Switch 1 error counter...

Page 38: ...with the value of switch 1 switch 2 and switch 3 on the DIP switch configuration If the result is an invalid setup the control will not enter Idle mode and instead enter Error Mode The control will ig...

Page 39: ...and try again Time out Exceeded Communication error Re aim external device and try again Encryption Error Incorrect machine type Before downloading ensure data is for current machine type Invalid Wak...

Page 40: ...round thermostat If problem persists replace control or thermostat ICM Lockout Alarm Active Rotation Sensor Error Check for broken or worn belts Make sure machine is not over loaded and check if rotat...

Page 41: ...have its data read without using the keypad It may also be used to start and stop various diagnostic tests How to Begin Communications with An External Device The control will go blank and the displa...

Page 42: ...Time Dry n a OFF 160 F 71 C 30 minutes 17 30 Min Low Time Dry n a OFF 140 F 60 C 30 minutes 18 30 Min No Heat Time Dry n a OFF n a 30 minutes 19 15 Min High Time Dry n a OFF 190 F 88 C 15 minutes 20...