Subject

Programming Timer

Use With Coin Slide Control

Coin Slide Control 

Power-Up Mode

When power is applied to the dryer, the control will 

enter the Ready Mode. If the control was powered 

down during a running a cycle, the 

IN USE

 LED will 

flash once and the control will enter Start Mode. If the 

dry time dipswitch settings have not been changed 

from factory default, the 

IN USE

 LED will flash once. 

Ready Mode

In Ready Mode, the control waits for the vend to be 

satisfied before entering Start Mode.

Start Mode

In Start Mode, the vend has been satisfied, but the 

Start button has not been pressed. The 

IN USE 

LED 

will be lit. The timer will not count down until the 

Start button is pressed.

Run Mode

In Run Mode, the control is running a cycle. The 

 

IN USE

 LED is lit.

Door Open Mode

In Door Open Mode, the control turns off the heater 

and motor when the door is opened during a run cycle. 

The timer will continue to count down time and the

 

IN USE

 LED is lit.

End of Cycle Mode

In End of Cycle Mode, a cycle is complete and the 

 

IN USE

 LED is off. The control remains in this mode 

until the door is opened or additional vend has been 

satisfied.

Topoffs

Any time the control receives a coin slide pulse during 

a cycle it will add the programmed dry time to the time 

currently remaining in the cycle. The 

IN USE

 LED 

will flash briefly to indicate the coin input. The 

maximum cycle time is 99 minutes. The control will 

not add time beyond 99 minutes. The cool down time 

will not change. If the control receives a coin slide 

pulse during cool down it will exit cool down and start 

heating with the cycle time equal to the programmed 

time.

Temperature Selector Switch

For five minutes after the control is powered up, there 

is a diagnostic feature that allows the temperature 

selector switches to be tested. When the temperature 

selector is changed, the new setting is displayed by 

flashing the 

IN USE 

LED as follows:

High/Normal: 4 flashes
Medium/PP: 3 flashes
Low/Delicate: 2 flashes
No Heat: 1 flash