© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Vending
512685
28
All Models
The control is shipped from the factory programmed
with 1 minute of minimum heat time, preset with 41
additional minutes of drying time (dipswitches 1, 4
and 6 in ON position) and 3 minutes of minimum cool
down time for a total time of 45 minutes for a coin
pulse. Refer to
Table 5
for dipswitch settings.
The control reads the dipswitch settings at power-up.
The control must be powered down to change the
dipswitch settings.
To change the heat or cool down time for a coin pulse,
the desired dry time dipswitches must be set to ON
position. All other dipswitches must be in OFF
position.
NOTE: The control must be powered down for 10
seconds before the dipswitch can be changed.
Models Starting Serial No 0909
Resetting Cycle Time to Zero
To remove any cycle time that may have accumulated
on the control during setup, the cycle time on the
control can be reset to zero.
To reset the time, unplug the dryer and set dipswitch 8
to ON position. Restore power to the dryer for 10
seconds and once again unplug dryer. Set dipswitch 8
to OFF position and restore power to the dryer.