5

 

 

 

 
 

 

Functions: Easykey in use

 

CHANGE MASTER CODE

 

By default Easykey has a Master Code 856069, which must be modified when it is installed. 

Each installation administrator-user can change it, following the sequence below:

 

 A+A+C+C+A+A+CURRENT MASTER CODE+A+NEW MASTER CODE+A 

 

ACTIVATE USER CODES

 

To enter a new code follow the sequence below:

 

 A+C+A+MASTER CODE+A+CODE 1+A+CODE 2+A+…+CODE N+A+C 

 

DEVICE OPENING WITH USER CODE

 

To open the device enter the user code followed by the letter A:

 

 CODE+A 

 

DEACTIVATE USER CODES

 

To cancel a code, follow the sequence below:

 

 C+A+C+MASTER CODE+C+CODE 1+C+CODE 2+C…+CODE N+C+A 

 

COMPLETE DEACTIVATION OF ALL USER CODES

 

To cancel / deactivate all the stored codes follow the sequence below:

 

 C+C+A+A+C+C+MASTER CODE+C 

 

CREATE/CHANGE FREE-ENTRANCE CODE

 

 A+A+A+C+C+MASTER   CODE+A+FREE-ENTRANCE  CODE+A 

 

ACTIVATE/DEACTIVATE FREE-ENTRANCE MODE

 

 FREE ENTRANCE CODE+A 

 

Summary of Contents for 76508L30 Series

Page 1: ...387 9951 www allgood co uk 76508L30 50R 76509L30 50R 76510U30 50R 76511U30 50R Issue 22 01 21 ELECTRONIC DIGITAL L SHAPED HANDLESET 2 14 8 6 10 2 15 4 5 3 21 7 1 12 3 6 9 13 13 13 13 17 18 11 7 13 20 19 14 15 012304 05 667304 05 ...

Page 2: ... 020 7387 9951 www allgood co uk 76508L30 50R 76509L30 50R 76510U30 50R 76511U30 50R Issue 22 01 21 ELECTRONIC DIGITAL L SHAPED HANDLESET 8 6 14 10 2 15 4 7 5 6 9 13 3 21 13 13 13 18 17 7 20 19 15 14 3 082304 05 607304 05 ...

Page 3: ...Codes The defaultmastercodeis 856069 It is recommendedto changethe mastercode whenthe digitalhandleisinstalled User Code Administrator can create a user code with 4 6 digits Max numberof usercodes Up to 150 user codes Security System After 5 wrong codes the lock is blocked for 1 minute Memory Information EEPROM usercodesremainin memory when the batteryis replaced Cycles 40 000 Signals Red and gree...

Page 4: ...E A ACTIVATE USER CODES To enter a new code follow the sequence below A C A MASTER CODE A CODE 1 A CODE 2 A CODE N A C DEVICE OPENING WITH USER CODE To open the device enter the user code followed by the letter A CODE A DEACTIVATE USER CODES To cancel a code follow the sequence below C A C MASTER CODE C CODE 1 C CODE 2 C CODE N C A COMPLETE DEACTIVATION OF ALL USER CODES To cancel deactivate all t...

Page 5: ...vershould facethe inside escutcheon and insert it in the spindle 5 leaving enough place to be able to connect the wires 6 Connect the wires 10 matching frompair 7 Push the inside escutcheon 9 towards the door Be careful not to trap the wires 8 Slim If youhavetoinstallthecylinder 11 insert itandfixinplacewithascrew 12 9 Slim Securethe entire lock in place using the 5 screws 13 provided Adapt Secure...

Reviews: