QUALITY SINCE 1948
T: 020 7387 9951
www.allgood.co.uk
76508L30/50R | 76509L30/50R | 76510U30/50R | 76511U30/50R
Issue 22/01/21
ELECTRONIC DIGITAL L SHAPED HANDLESET
5
Functions: Easykey in use
CHANGE MASTER CODE
By default Easykey has a Master Code 856069, which must be modified when it is installed.
Each installation administrator-user can change it, following the sequence below:
A+A+C+C+A+A+CURRENT MASTER CODE+A+NEW MASTER CODE+A
ACTIVATE USER CODES
To enter a new code follow the sequence below:
A+C+A+MASTER CODE+A+CODE 1+A+CODE 2+A+…+CODE N+A+C
DEVICE OPENING WITH USER CODE
To open the device enter the user code followed by the letter A:
CODE+A
DEACTIVATE USER CODES
To cancel a code, follow the sequence below:
C+A+C+MASTER CODE+C+CODE 1+C+CODE 2+C…+CODE N+C+A
COMPLETE DEACTIVATION OF ALL USER CODES
To cancel / deactivate all the stored codes follow the sequence below:
C+C+A+A+C+C+MASTER CODE+C
CREATE/CHANGE FREE-ENTRANCE CODE
A+A+A+C+C+MASTER CODE+A+FREE-ENTRANCE CODE+A
ACTIVATE/DEACTIVATE FREE-ENTRANCE MODE
FREE ENTRANCE CODE+A