background image

@lgood 

� 

Installation 

instructions:

Servicing instructions 

The minimum service period for the 

dryer should be every 3 months or 

more frequent intervals as experience 

dictates: 

1. Isolate the Hand Dryer from the

electricity supply before servicing.

2. Remove dust, fluff and any other

build up of foreign matter from

inlet and outlet grille areas

(Illustration 3).

T: 020 7387 9951  

  4  

  www.allgood.co.uk

 

Fixing Instructions: 2461N Surface mounted hand dryer

FI2461N

Issue 03-08/22

@lgood 

� 

IMPORTANT 

Read these instructions before 

commencing with the installation.

DO NOT install this product in areas where the 

following may be present or occur: 

Corrosive 

or 

flammable gases, liquids or vapours.

Ambient temperatures higher than 40

°

( or less

than -5

°

C.

Possible obstructions which would hinder the

access or removal of the hand dryer.

Safety and guidance notes 

A. All wiring to be in accordance with

the current I.E.E. Regulations, or the

appropriate standards of your

country and MUST be installed by a

suitably qualified person.

B.

The Hand Dryer should be provided

with  a  local  isolator switch  capable

of  disconnecting  all  poles,  having a

contact separation of at least 3mm.

C. Ensure that mains supply (Voltage,

Frequency, and Phase) complies with

the rating label.

D.

The Hand Dryer should only be used

in conjunction with fixed wiring.

E.

The Hand Dryer should not be 

used

where it is liable to be subject to

direct water spray for prolonged

periods of time.

F.

This appliance can be used by

children aged 8 and above and

persons with reduced physical, 

sensory 

or 

mental capabilities or lack 

of experience and knowledge if they 

have been given supervision or 

instruction concerning use of the 

appliance in a safe way and 

understand the hazards involved. 

Children should be supervised to 

ensure that they do not play with 

the appliance.Cleaning and user 

maintenance shall not be made by 

children without supervision. 

G.

  Stationary appliances not fitted with

means for disconnection from the

supply mains having a contact

separation in all poles that provide

full disconnection under over

voltage category 111, the instructions

state that means for disconnection

must be incorporated in the fixed

wiring in accordance with the

wiring rules.

T:

 

020

 

7387

 

9951

 

 

1

 

 

www

.allgood.co.uk

Fixing Instructions: 2461N Surface mounted hand dryer

FI2461N

Issue 03-08/22

1. Drill 7mm dia. x 50mm deep four places

using template FT2461N supplied 

to

mark up position (For fitting to masonry).

2.

Insert nylon plugs.

3.

Locate Dryer sub assy; insert screws

through black nylon collar, plain washer,

grommet, into plugs and fully tighten.

4.

Connect the wiring to

the unit as outlined in the Wiring

Instructions (Page 2).

5.

Locate cover over back plate ledge, pull

down, roll back and tighten screws from

underneath (Illustration 2).

IMPORTANT 

After installation or servicing, units must be checked, and 

only left when electrically and mechanically safe.

2.

3.

Reviews: