Page 1: ...LUBMATIC ELECTRICAL LIQUID GREASE PUMPS INTRODUCTION AND USER MANUAL VERSION 2 00 ...

Page 2: ...ill be increased INTRODUCTION ABOUT MANUFACTURER With over 25 years experience of manufacturing Centralized Lubrication Systems ALLFETT is able to provide a wide professional approach to select the correct Centralized Lubrication System for industry and heavy machinery A highly accurate manufacturing process is involved in producing Centralized Lubrication Systems in order that systems meet the ve...

Page 3: ...RODUCT DIMENSIONS PRODUCT COMPONENTS FUNCTION LUBRICANT INFORMATION ELECTRICAL CONNECTION RULES TO COMPLY WHILE USING AND WARRANTY CONDITIONS PUMP MAINTENANCE ORDER INFORMATION WARRANTY WARRANTY CONDITIONS PAGE 1 PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 6 PAGE 7 PAGE 8 PAGE 9 10 PAGE 11 PAGE 12 PAGE 13 PAGE 14 ...

Page 4: ...ide wide range of facility LUBMATIC type pumps produced with different types depends on reservoir capacities and optional components Pressure relief valve and mechanical by pass system is standard and integrated with pump design PRODUCT DESCRIPTION GENERAL SPECIFICATIONS For more information about which distributors can be used with LUBMATIC pumps please call ALLFETT technical service Lubmatic ser...

Page 5: ... 1 8 Liters 3 3 Liters Width Height Depth D1 D3 A w A n 4 Liters 4 5 Liters 6 Liters D2 Reservoir 1 Liter 1 5 Liters 1 8 Liters 3 3 Liters 4 Liters 4 5 Liters 6 Liters Height 284mm 303mm 347mm 376mm 323mm 406mm 386mm Width 182mm 202mm 182mm 202mm 221 5mm 202mm 221 5mm Depth 150mm 184mm 150mm 184mm 222mm 184mm 222mm D1 130mm 158mm 130mm 158mm 210mm 173mm 210mm D2 8 mm D3 A w 114 5mm 133mm 114 5mm 1...

Page 6: ... below Follower piston is optional component and can only be used with 6 liters reservoir Reservoir with piston must be filled by quick filling coupling Filling cover Reservoir Pump system Assembly holes Saplama Reservoir cover Exhaust Follower piston system Optional Assembly holes Pressure switch T coupling Outlet coupling Motor cover Low level indicator optional Quick filling coupling optional O...

Page 7: ...c control card pass to waiting period Control card will stay on waiting period as long as programmed time value ends By pass system discharge the lubricant inside main lubrication line after motor stops All distributors are set up again and get ready to next lubrication cycle LUBMATIC pumps are designed to use with single line system distributors If necessary progressive distributors can be used w...

Page 8: ...se informations Lubricant type Oil NLGI 000 and NLGI 0000 class liquid grease can be used with LUBMATIC pumps Because of the flow characteristics of liquid grease the NLGI class range should be changed at different weather conditions and also temperature differencies Lubricant type Liquid grease Liquid grease must maintain fluidity condition at any temperature while using Liquid grease must not be...

Page 9: ... socket Transformer is necessary if there is no 24 V DC electrical source Use minimum 30A current transformer All electrical connections and lines must be checked regularly for damage and to ensure that they are firmly in place Pumps have an electric driven motor Electrical motor and pressure switch connection cables must be connected properly as described in schema below Electrical motor cables P...

Page 10: ...ng voltage to product DISQUALIFIES THE WARANTY All electrical connections and lines must be checked regularly for damage and to ensure that they are firmly in place 6 Pumps have an electric driven motor Electrical lines must be connected properly as described in ELECTRICAL CONNECTIONS section of this manual and applied only by qualified and instructed personel 5 Pump reservoir is made of transpare...

Page 11: ...d aids prohobited and DISQUALIFIES THE WARANTY Only maintenance may apply descibed in PAGE 14 15 ALLFETT Technical Service must be informed to any other possible troubles and necessary procedures must be performed 18 ALLFETT Mekanik ve Elektronik Sistemler SAN TIC LTD STI and ALLFETT Pazarlama ve Dis Ticaret LTD STI does not accept responsibility for damages described in items above on equipments ...

Page 12: ...it until programmed waiting period or operate a manual lubrication cycle by pressind ADDITIONAL CYCLE button on control unit Please refer to EK 10 electronic control card manual for more information about control unit a b c d 2 Pump is working but not sending lubricant and Pole connections of electrical cables may connected reverse Check the electrical cables and connections of the system accordin...

Page 13: ...6 B1 12 V DC 1 liter 1 5 liters 1 8 liters 3 3 liters 4 liters 4 5 liters 6 liters LUBMATIC oil and liquid grease pump 10 24 01 B1 10 24 15 B1 10 24 18 B1 10 24 33 B1 10 24 04 B1 10 24 45 B1 10 24 06 B1 24 V DC 1 liter 1 5 liters 1 8 liters 3 3 liters 4 liters 4 5 liters 6 liters LUBMATIC oil and liquid grease pump 10 12 06 P0 10 24 06 P0 12 V DC 24 V DC 6 Liters with piston 6 Liters with piston S...

Page 14: ...PANY FAX TELEPHONE CENTRAL ADRESS NAME ALLFETT Mekanik ve Elektronik Sistemler San ve Tic Ltd Þti 0212 501 33 37 0212 501 32 01 PBX Yeni Eyup Bulvari Topcular Cad Set Ustu No 1 Demirkapý Rami Ýstanbul AUTHORISED PERSON SIGNATURE STAMP PRODUCT TYPE Electrical oil and liquid grease pump BRAND ALLFETT MODEL SERIAL NUMBER DELIVERY DATE PLACE WARRANTY 2 years REPAIR TIME SALER COMPANY NAME CENTRAL ADRE...

Page 15: ...d expenses of any sort including labor the value of the parts replaced or any our charges The product will be replaced free of charge If the product permanently disfunctions due to repeating the same defect more than four times within the warranty period If the maximum period for repairing is exceeded If it is determined that the defect cannot be repaired by report written by the service or in the...