PAGE
7
www.allfett.net
LUBRICANT INFORMATION
Lubricant specifications can be used with LUBMATIC pumps are described below. Before filling
reservoir please read carefuly these informations.
Lubricant type - Oil
NLGI 000 and NLGI 0000 class liquid grease can be used with LUBMATIC pumps.
Because of the flow characteristics of liquid grease the NLGI class range should be changed at
different weather conditions and also temperature differencies.
Lubricant type - Liquid grease
Rubber based lubricant types must not be used in the system.
Only LITHIUM based and EP additive liquid grease must be used with in system.
Liquid grease must maintain fluidity condition at any temperature while using. Liquid
grease must not be used if gets harder and loose fluidity at cold temperatures.
LUBMATIC pumps are designed to use with in centralized lubrication systems only. It
is not suitable to use LUBMATIC pump for lubricant tranfering or circulation purpose.
Filling filter must be checked after each filling. Cleaning filter is important at regular
time intervals.
Lubricant will be used in the system must certainly be clean and any foreign materials
must not enter while filling.
ISO viscosity 40 to 220 grade oils can be used with LUBMATIC pumps.
It is recomended that the oil will be used in the system should be resistant to higher temperatures,
and maintain the viscosity characteristics. Additionally oil should provide lubricant film stability,
water resistance and corrosion protection abilities.
Keep in mind that the substances of any lubricant are harmfull to environment. Their
transport and storage require that special safety measures be taken.
Summary of Contents for LUBMATIC Series