background image

5

Weekly Maintenance:

•Thoroughly clean humidifier every week as described in Daily Maintenance.

• Remove the water reservoir (d), the steam chamber (c), and the heating cone (g) from the appliance

and rinse all parts with vinegar water (25% vinegar / 75% water). Rinse thoroughly with clean water 
after that.

•Remove any residual water from the water reservoir. Fill the reservoir with a mixture of 25% vinegar 

(950ml) and 75% water (2850ml) and leave for 20 minutes to remove possible mineral deposits. Drain 
vinegar water and rinse thoroughly with clean water.

• Fill the heating chamber (e) with vinegar (50% vinegar / 50% water) and leave it to take effect for 20 

minutes. Drain any residual water from the heating chamber and dry with damp soft clean cloth. 

WARNING: Do not submerge or rinse the base in water.

- Do not use steel wool, scouring agents or abrasive material.
- Dry all parts properly.
- Reassemble the appliance as shown in the instruction manual.

Disinfecting the Removable Heating Cone and Water Reservoir:

• Thoroughly clean humidifier every week using a solution of bleach and water (1 tea spoon of bleach 

in 3.8 litre of water). Fill the reservoir partially with this solution and let it stand for 20 minutes shaking the
water reservoir vigorously every few minutes. Drain and rinse the reservoir with clean water until the 
bleach smell is gone.

• The Heating Cone, Aromatic container, and Steam Chamber are dishwasher safe.

N.B.:

 Place on the top shelf of the dishwasher only.

End of Season Maintenance:

• Thoroughly follow Weekly Maintenance directions above. Make sure all parts of the humidifier are dry

before storing.

• Leave the reservoir cap partially loosened during storage to prevent the reservoir cap and gasket from

sticking together.

• Clean the reservoir and base after a long period of storage.

Summary of Contents for HIPPO Deluxe

Page 1: ...INSTRUCTIONS ...

Page 2: ...r commercial industrial or outside use Position the appliance on a flat stable water resistant surface Do not use this appliance near bath tubs washbasins large water receptacles or expose it to rain and moisture Do not expose to outside elements or direct sunlight Do not immerse base in water and ensure that no water enters into appliance s interior Do not block or obstruct air vents Keep ventila...

Page 3: ...n on the rating label Do not connect appliance to a direct current DC supply Repairs must be carried out by an authorised service Centre Unauthorised repairs may void warranty and could be a potential electrical hazard INSTRUCTIONS FOR USE 1 Grasp the handle of the water tank firmly and remove it from the base Fig 1 2 Remove the cap from the water reservoir by turning it counter clockwise Fig 2 Fi...

Page 4: ... HIPPO Deluxe will shut off automatically 10 Switch off the appliance disconnect the power cord and let it cool off for 15 minutes before refilling the water reservoir 11 Always rinse the water reservoir after each use Caution The steam is very hot Please keep your feet and hands away from the steam discharge opening Do not operate the air humidifier close to children Danger of burning COMPONENT L...

Page 5: ...m base d and rinse it with warm water thoroughly a couple of times Repeat this process every time before refilling the appliance with water prior to using Wipe accessible surfaces of the water reservoir with a soft cloth Remove the Aromatic container from the Steam Chamber c Fig 6 Using the Heating Cone release Fig 7 release the Steam Chamber Fig 8 from the Base Wipe the Aromatic container Steam C...

Page 6: ...ot use steel wool scouring agents or abrasive material Dry all parts properly Reassemble the appliance as shown in the instruction manual Disinfecting the Removable Heating Cone and Water Reservoir Thoroughly clean humidifier every week using a solution of bleach and water 1 tea spoon of bleach in 3 8 litre of water Fill the reservoir partially with this solution and let it stand for 20 minutes sh...

Page 7: ...reservoir The heating element is encrusted with scale and the protection thermostat has tripped Tank may be leaking Tank Cap is loose SOLUTION Plug the unit in Have the circuits fuses and test outlet with a tester Fill reservoir with water Place on a level surface Clean the Heater and Removable Heat Cone as specified in the Weekly maintenance Rinse thoroughly with clean water and dry Open room doo...

Page 8: ...nating current Warning follow the Instructions for use Warranty 5 years from date of purchase does not include damage due to misuse negligence or calcification of the heating element Please retain your purchase receipt as proof of purchase must be presented if making a claim under warranty Ebos Group P L reserves the right to make technical changes to this product with out prior notice For service...

Reviews: