7
CARE AND MAINTENANCE
• Clean carefully by gently wiping with a grit-free damp cloth.
• Use only mild soap with water.
• Never use acids, harsh chemicals, or abrasive detergents to clean the faucet surface.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
There is no hot or
cold water.
The water inlet hose was
accidentally kinked during
installation and is limiting the water
flow through.
Reinstall the water inlet hose.
There are leaks
underneath the handle.
The bonnet nut has come loose and
the O-ring on the cartridge is dirty or
damaged.
Tighten the bonnet nut. Clean or
replace the O-ring.
The aerator leaks or has
an inconsistent water
flow pattern.
1. The aerator is dirty or misfitted.
2. The cartridge may be clogged.
1. Remove the aerator and check
for debris in the aerator screens.
2. Remove the cartridge and check
for debris.
3. Ensure the aerator is properly
installed.
The water pressure is
low.
1. The connector underneath the
deck is clogged with debris.
2. The aerator is clogged.
1. Turn off the water supply and
disconnect the connector/aerator.
2. Unscrew the connector/aerator
and clean under running water.
3. Screw the connector/aerator
back.
4. Test water flow. If water pressure
is still low then replace the
connector/aerator.