background image

ASSEMBLY INSTRUCTIONS

7

5.

6.

Unwrap BARE fixture wire from BLACK and WHITE 
fixture wires. Prepare wires by stripping 3/4 in. of 
insulation from wire ends using wire strippers (not 
included). Connect WHITE wire from fixture (A) to 
WHITE wire from outlet box using existing wire 
connector or wire connector (AA). Connect BLACK 
wire from fixture (A) to BLACK wire from outlet box 
using existing wire connector or wire connector (AA). 
Connect BARE/GREEN ground wire from outlet box 
to BARE ground wire from fixture (A) with wire 
connector (AA).  

NOTE:

 Screw wire connectors (AA) on in a clockwise 

direction.

       

WARNING:

 Never connect ground wire to 

WHITE or BLACK power supply wires.

      WARNING: 

To reduce the risk of fire, electrical 

shock or personal injury, wire connectors (AA) are 
designed to accept only one 12-gauge house wire 
and two lead wires from the light fixture. If your 
house wire is larger than 12-gauge or there is more 
than one house wire to connect to the corresponding 
fixture lead wires, consult an electrician for the 
proper size wire connectors to use.

Hardware Used

Wire Connector

  x 3

AA

Wrap electrical tape (not included) around 
each individual wire connector (AA) down 
to the wire. Push wire connectors (AA) 
gently back into outlet box. Carefully push 
excess wiring into outlet box. 

       

WARNING:

 Make sure no bare wire or 

wire strands are visible after making 
connections.

6

Outlet Box

WHITE

A

AA

AA

A

AA

AA

BARE/

GREEN

AA

AA

BLACK

5

Summary of Contents for 0760083

Page 1: ...ssing parts Before returning to your retailer call our customer service department at 1 866 439 9800 8 a m 8 p m EST Monday Sunday 1 Purchase Date allen roth is a registered trademark of LF LLC All Rights Reserved Français p 10 Español p 19 ATTACH YOUR RECEIPT HERE welcoming sophisticated inspiring BM19435 ...

Page 2: ...nting Plate 1 C Mounting Plate Screw 2 preassembled to fixture A preassembled to fixture A C B A Package Contents 2 Hardware Contents 3 Safety Information 3 Preparation 5 Assembly Instructions 5 Care and Maintenance 8 Troubleshooting 9 Warranty 9 TABLE OF CONTENTS ...

Page 3: ...s injury or death DO NOT connect the bare or green insulation fixture ground wire to the black HOT current carrying wire or the white NEUTRAL house wire Connection of the bare or green fixture ground wire to the black or white house wires may cause metal parts of the fixture to carry electrical currents Under this condition anyone coming in contact with the fixture will receive electrical shock wh...

Page 4: ...ssibility of personal injury and the danger of electrical shock or fire To reduce the risk of fire electrical shock or personal injury wire connectors provided with this light fixture are designed to accept only one 12 gauge house wire and two lead wires from the light fixture If your house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fixture le...

Page 5: ...TIONS Before beginning assembly of product make sure all parts are present Compare parts with package contents list and hardware contents list If any part is missing or damaged do not attempt to assemble the product Estimated Assembly Time 30 minutes Tools Required for Assembly not included Flathead Screwdriver Phillips Screwdriver Wire Strippers Pliers Wire Cutters Safety Glasses Stepladder Elect...

Page 6: ...et box screws or the machine screws BB NOTE If the outlet box screws required for your outlet box are of a different size than the machine screws BB consult a licensed electrician before proceeding Tighten machine screws BB to secure mounting plate B CAUTION The fixture must be mounted to an outlet box that is supported by the building structure Plastic outlet boxes are not recommended 3 4 Hardwar...

Page 7: ...t ground wire to WHITE or BLACK power supply wires WARNING To reduce the risk of fire electrical shock or personal injury wire connectors AA are designed to accept only one 12 gauge house wire and two lead wires from the light fixture If your house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fixture lead wires consult an electrician for the pro...

Page 8: ...ore tightening mounting plate screws C completely use level not included to check fixture A adjust if necessary Restore power and test fixture A If lights do not function please refer to TROUBLESHOOTING 8 CARE AND MAINTENANCE Shut off main power supply Wipe with soft cloth or use window cleaner Do not use an abrasive cleaner 7 8 B A C C A ...

Page 9: ...lation and specifically excludes liability for direct incidental or consequential damages improper packaging of returned products and acts of God As some states do not allow exclusions of limitations on an implied warranty the above exclusion and limitation may not apply This warranty gives you specific rights and you may also have other rights which may vary from state to state Light does not com...

Reviews: