
3, 8, or 16 Axis SERCOS interface Module
21
Publication
1756-IN572E-EN-P – March 2004
Removing the Module from the Chassis
To remove the module from the chassis:
1 .
Push in and hold the top and bottom locking tabs on the module.
Figure 8 Hold locking Tabs
Off
The module has detected no ring
data on its receiver or has not
successfully completed phase 2.
Check your system and
installation as follows:
•
Make sure all cables are
properly installed
•
Inspect cable for
degradation and
breakage.
•
Inspect drives for faults.
Flashing green
The ring, drive, or axes are not
configured but, at least one has
been identified.
Not a problem if the system has
not been configured. If you are
having trouble configuring the
ring, drive, and axes:
Make sure that the application
program is setup properly for the
equipment in use.
If the
SERCOS
Ring LED
displays:
Then the ring status is:
Take this action:
POWER
OK
SERCOS interface
Allen-Bradley PLCs