Before you begin

This publication guides you through the remaining processes required to initialize a 
ProcessLogix Server. You are required to finalize the Server installation by completing the 
instructions outlined in this document.
This document does not contain complete instructions covering the installation process, and 
refers you to procedures contained in other documentation. For a successful installation, have 
the following documents available:

ControlNet PCI Communication Interface Card Installation Instructions

, publication 

1784-IN003, shipped with the 1784-PCIC card.

ProcessLogix R500.1 Installation and Upgrade Guide

, publication 1757-IN500, shipped 

with the ProcessLogix R500.1 Software Kit.

These and other ProcessLogix documents can be found on The Automation Bookstore, at 
http://www.theautomationbookstore.com/. The following table lists items that you MUST 
complete before attempting to use the ProcessLogix Server.

Step

Item

Page

1.

Installing the 1784-PCIC Card

3

2.

Installing the Windows 2000 license and Warranty Transfer

4

3.

Logging on to Windows 2000

5

4.

Configuring the 1784-PCIC Card

5

5.

Changing the PC Name

5

6.

Changing the Network Settings

6

7.

Setting the Date and Time

8

8.

Creating an Emergency Repair Disk

8

9.

When finished, click OK.

8

10.

Changing the ProcessLogix License

10

Allen-Bradley PLCs

Summary of Contents for ProcessLogix R500.1

Page 1: ...ace Card Installation Instructions publication 1784 IN003 shipped with the 1784 PCIC card ProcessLogix R500 1 Installation and Upgrade Guide publication 1757 IN500 shipped with the ProcessLogix R500 1...

Page 2: ...len Bradley publication SGI 1 1 Safety Guidelines for the Application Installation and Maintenance of Solid State Control available from your local Rockwell Automation office describes some important...

Page 3: ...Web Support http www ab com under Support click Product Support Your Questions or Comments about this Manual If you find a problem with this manual please notify us by using the How are We Doing form...

Page 4: ...If there is a delay click Restart Now setup will automatically restart the PC 8 In order to receive support from Dell you must fill out their warranty transfer form On the form enter Rockwell in the...

Page 5: ...apter 7 of the ProcessLogix R500 1 Installation and Upgrade Guide for details Changing the PC Name TIP You must repeat the above steps every time you reboot the Server IMPORTANT If you purchased a new...

Page 6: ...ou must make certain that the PC names and IP addresses are unique i e PLX1 PLX2 The base name cannot contain more than 13 alphanumeric characters and must contain no spaces The full computer name can...

Page 7: ...1 Backup Redundant Server NIC 1 192 168 0 2 NIC 2 192 168 1 2 NIC 3 192 168 2 2 IMPORTANT IP Addresses are critical to the communication of the system Rockwell Automation suggests when possible to uti...

Page 8: ...d Click OK Creating an Emergency Repair Disk 1 Insert a blank diskette into the PC s floppy drive 2 Click Start Programs Accessories System Tools Backup 3 Click Emergency Repair Disk 4 An Emergency Re...

Page 9: ...r C for example appears in the To Drive field in the dialog box 6 Click OK to initiate the move 7 Click Move to move the file to the hard drive Wait for a dialog box to give a successful move indicati...

Page 10: ...lick the Database Only option b Click Yes to confirm the action and wait for the Server to change its state c Close the ProcessLogix Server dialog box 2 Click Start Programs ProcessLogix Server Setup...

Page 11: ...kbox and click Finish 9 Reboot the computer To verify your license 1 Click Start Programs ProcessLogix Server Setup 2 At the Welcome window click Next 3 Select the View software license details checkb...

Page 12: ...s reserved Printed in the U S A ProcessLogix ControlNet and Allen Bradley are trademarks of Rockwell Automation Inc Windows 2000 is a registered trademark of the Microsoft Corporation Dell is a regist...

Reviews: