94
Rockwell Automation Publication 20P-TG001C-EN-P - February 2018
Chapter 3
Part Replacement Procedures
13. Remove the wires that connect the field fuses (UF, UF1, VF, VF1) to the
field circuit board.
14. Remove the wire from connector X3 on the field board.
Install the Field SCR/Dual Diode Module and Field Circuit Board
• Install the field SCR/dual diode bridge module and field circuit board
in reverse order of removal.
IMPORTANT
Thermal grease must be applied to the bottom of the field SCR/dual diode
module before securing it to the heat sink.
IMPORTANT
Verify that the field circuit wires are connected to the correct location on the
field SCR/dual diode module.
ID
Wire Description
Signal
ID
Wire Description
Signal
1
Thick brown
To field circuit board
5
Thick red
To field circuit board
2
Thick blue
To field circuit board
6
Thin red
3
Thick black
To field circuit board
7
Thin black
4
Thin blue
13
Field fuses
14
5 and 6
1
4
7
2
3