62
Rockwell Automation Publication 20P-TG001C-EN-P - February 2018
Chapter 3
Part Replacement Procedures
6. Remove the two stand-offs from the control board.
Install the 115V AC to 24V DC I/O Converter Circuit Board
Install the 115V AC to 24V DC I/O converter board in reverse order of
removal.
Control Circuit Board
Replacement
Remove the Control Circuit Board
Follow these steps to remove the control circuit board.
1. Save the drive and adapter parameter configuration to a HIM Set or by
down loading the drive and adapter parameters to an offline database file
using DriveExecutive™. See the PowerFlex DC Digital Drive User
Manual, publication
, for information on using the HIM.
See the on-line Help provided with DriveExecutive for more
information on HIM Sets or using the HIM.
2. Read the General Safety Precautions on page
3. Remove power from the drive (see page
4. Remove the protective covers (see page
).
5. Remove the communication adapter and EMI shield from the control
board (see page
6. If installed, remove the I/O expansion circuit board (see page
).
7. If installed, remove the 115V AC to 24V DC I/O converter circuit
board (see page
6
Tightening torque:
1.0 N•m (8.9 lb•in)