26
Rockwell Automation Publication 20HIM-UM001E-EN-P - May 2017
Chapter 3
HIM Components
LCD Display Elements
The basic HIM screen is divided into three display zones, which are shown in
Figure 3
and described in their respective subsections that follow.
Figure 3 - HIM Display Zones
Status Bar
The Status Bar provides operating status information for the host drive.
Data Area
The Data Area displays the data or function presently being acted upon.
Status Bar
Data Area
Soft Key Labels
00
Stopped
0.00 Hz
AUTO
Host Drive
240V
4.2A
20G...D014
ESC
REF
TEXT
F
PAR#
Stopped
0.00 Hz
AUTO
F
Status Bar Element
Meaning
Host Icon
A small image of the connected host drive.
Stopped
Status Text
Indicates present host drive operating status.
Text flashes when a fault is present.
0.00 Hz
Feedback
Indicates drive output feedback (for example, Hz, RPM, amps, etc.)
AUTO/MAN
Mode Indication
Indicates Auto or Manual HIM status.
Alarm Indication
Bell icon indicates that an alarm is present.
F
or
R
(not shown)
Rotation Indication
Indicates Forward or Reverse direction of host drive operation.
DLX
(not shown)
DeviceLogix™ Indication
Indicates when the host drive DeviceLogix feature is enabled.
Data Area Element
Meaning
Host or Device Icon
Image of the host drive or image of the device connected to the port
selected.
00
Port Selection
Indicates selected port. Use the
or
navigation keys to
select a port.
Host Drive
User-Definable Text
Top line of text in the Data Area can be edited by the user.
00
Host Drive
240V
4.2A
20G...D014
Summary of Contents for PowerFlex 20-HIM-A6
Page 4: ...4 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Summary of Changes Notes ...
Page 8: ...8 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Table of Contents Notes ...
Page 66: ...66 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Chapter 4 Using the HIM Notes ...
Page 70: ...70 Rockwell Automation Publication 20HIM UM001E EN P May 2017 Appendix B HIM Parameters Notes ...