C-6
ControlNet Objects
Class Code
Instances
The number of instances depends on the number of parameters in the
DPI drive. The adapter parameters are appended to the list of drive
parameters. The total number of parameters can be read in Instance 0,
Attribute 2.
Class Attributes
Parameter Object
Hexadecimal Decimal
0x0F
15
Instance
Description
0
Class Attributes
1
Drive Parameter 1 Attributes
…
…
n
Last Drive Parameter Attributes
n + 1
Adapter Parameter 1 Attributes
…
…
n + 27
Last Adapter Parameter Attributes
Attribute
ID
Access
Rule
Name
Data Type Description
1
Get
Revision
UINT
1
2
Get
Max Instance
UINT
Number of parameters
8
Get
Parameter
Class
Descriptor
WORD
Bits that describe parameters.
9
Get
Configuration
Assembly
Instance
UINT
0
10
Set
Native
Language
USINT
0 = English
1 = French
2 = Spanish
3 = Italian
4 = German
5 = Japanese
6 = Portuguese
7 = Mandarin Chinese
8 = Russian
9 = Dutch
20COMM-UM003A-EN-P.book Page 6 Wednesday, November 7, 2001 3:46 PM
Summary of Contents for PowerFlex 20-comm-c FRN 1. Series
Page 6: ...iv Table of Contents Notes 20COMM UM003A EN P book Page iv Wednesday November 7 2001 3 46 PM...
Page 18: ...1 8 Getting Started 20COMM UM003A EN P book Page 8 Wednesday November 7 2001 3 46 PM...
Page 114: ...B 6 Adapter Parameters Notes 20COMM UM003A EN P book Page 6 Wednesday November 7 2001 3 46 PM...
Page 152: ...Glossary 6 Notes 20COMM UM003A EN P book Page 6 Wednesday November 7 2001 3 46 PM...
Page 154: ...20COMM UM003A EN P book Page 2 Wednesday November 7 2001 3 46 PM...