Rockwell Automation Publication 750-IN001O-EN-P - October 2014
123
Lift and Mount the Drive
Chapter 3
Disconnect Wire Connections
- No Drive Control Pod
This procedure applies to Frame 8 drives with a remotely mounted drive control
pod (up to 23 m or 75 ft away) and to the right hand cabinets of Frame 9 and
larger drives.
1.
Remove the right front cover.
2.
Disconnect the 24V wire harness
➊
from TB1.
3.
Disconnect the fiber-optic cable
➋
from INV on the power layer interface
board.
T20 or F 6.4 mm (0.25 in.)
1.8 N•m (16.0 lb•in)
Floor Mount Frame 9 Shown