70
Rockwell Automation Publication 2711P-AP006C-EN-P - November 2018
Chapter 7
Qualify the Runtime Application
Follow These Steps
Follow these steps to configure diagnostics, validate, test run, configure global
memory connections, download, and run your converted application on a
PanelView Plus 7 terminal.
Review Diagnostic Lists
On your development computer, FactoryTalk View ME software features a
diagnostic list at the bottom of the application window. You can configure
FactoryTalk diagnostics to display information, warnings, and errors during
application development and runtime.
When you test run your application, the diagnostic list displays messages and
errors that are logged by the application. Use this list to identify the graphic
objects or features that generated the messages or errors. Correct these errors
during the validation process.