     Micro820 20-Point Programmable Controllers

Publication 2080-IN009B-EN-P - April 2014

Additional Resources

If you would like a manual, you can:

• download a free electronic version from the Internet: 

http://rockwellautomation.com/literature

• purchase a printed manual by contacting your local Allen-Bradley distributor or 

Rockwell Automation representative

ATTENTION: 

To comply with the CE Low Voltage Directive (LVD), this equipment must be 
powered from a source compliant with the following: Safety Extra Low 
Voltage (SELV) or Protected Extra Low Voltage (PELV).

To comply with UL restrictions, this equipment must be powered from a 
Class 2 or Limited Voltage Limited Current Source (LVLC).

For Class I Division 2 applications, use only Class I Division 2 listed or 

recognized accessories and modules approved for use within the Micro800

®

 

platform.

ATTENTION: 

Electrostatic discharge can damage semiconductor devices inside the 
module. Do not touch the connector pins or other sensitive area pins.

Be careful when stripping wires. Wire fragments that fall into the controller 
could cause damage. Once wiring is complete, make sure the controller is 
free of all metal fragments.

Do not connect directly to line voltage. Line voltage must be supplied by a 
suitable, approved isolating transformer or power supply having short 
circuit capacity not exceeding 100 VA maximum equivalent.

Resource

Description

Micro820™ 20-point Programmable 
Controllers User Manual, publication 

2080-UM005

A more detailed description of how to install and use your 
Micro820 programmable controller.

Micro800

®

 Plug-in Modules User Manual, 

publication 

2080-UM004 

Installation and wiring descriptions for the different Micro800 
plug-in modules. 

Micro800 AC Power Supply Installation 
Instructions, publication 

2080-IN001

Information on wiring and installing the optional AC power supply.

Micro820 Remote LCD Installation 
Instructions, publication 

2080-IN010

Information on wiring and installing the Micro800 Remote LCD, 
2080-REMLCD.

Industrial Automation Wiring and 
Grounding Guidelines, publication 

1770-4.1

More information on proper wiring and grounding techniques.

Summary of Contents for Micro820

Page 1: ...e aparece acima para encontrar e fazer download da publica o IT Questa pubblicazione disponibile in Italiano in formato PDF Per scaricarla collegarsi al sito Web indicato sopra ZH DE Diese Publikation...

Page 2: ...lation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use...

Page 3: ...e the spread of flame complying with a flame spread rating of 5VA or be approved for the application if nonmetallic The interior of the enclosure must be accessible only by the use of a tool Subsequen...

Page 4: ...ereux Lorsque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature glob...

Page 5: ...codes Exposure to some chemicals may degrade the sealing properties of materials used in the Relays It is recommended that the User periodically inspect these devices for any degradation of properties...

Page 6: ...her sensitive area pins Be careful when stripping wires Wire fragments that fall into the controller could cause damage Once wiring is complete make sure the controller is free of all metal fragments...

Page 7: ...ted on the same DIN rail as the controller Controller Overview Controller Description Description Description 1 Status indicators 7 Plug in latch 2 Optional power supply panel mounting latch hole 8 Pl...

Page 8: ...reduce the effects of electrical interference and environmental exposure Locate your controller as far as possible from power lines load lines and other sources of electrical noise such as hard contac...

Page 9: ...Mounting The module can be mounted using the following DIN rails 35 x 7 5 mm and 35 x 15 mm EN 50 022 35 x 7 5 and EN 50 022 35 x 15 Before mounting the module on a DIN rail use a flat blade screwdriv...

Page 10: ...le spacing tolerance 0 4 mm 0 016 in Follow these steps to install your controller using mounting screws 1 Place the controller against the panel where you are mounting it Make sure the controller is...

Page 11: ...croSD card pull it out and change the orientation WARNING When you insert or remove the microSD card while power is on an electrical arc can occur This could cause an explosion in hazardous location i...

Page 12: ...fer to the Micro820 Programmable Controllers User Manual publication 2080 UM005 for suitable surge suppression methods and recommended surge suppressors Minimizing Electrical Noise on Analog Channels...

Page 13: ...n Modules Wiring diagrams for your Micro800 plug in modules are available in the Rockwell Automation Literature Library http rockwellautomation com literature Wire the Controller Serial Port Terminal...

Page 14: ...OM0 I 04 I 05 I 08 I 07 1 2 3 4 5 6 7 8 9 10 11 12 DC24 DC24 VO 0 DC24 NU CM0 O 00 CM1 CM2 O 01 O 03 O 02 1 2 3 4 5 6 7 8 9 10 11 12 I 10 I 09 NU I 11 13 14 15 16 O 04 CM3 O 06 O 05 13 14 15 16 I 06 4...

Page 15: ...r removable and fixed terminal blocks 0 5 0 6 Nm 4 4 5 3 lb in using a 0 6 x 3 5 mm flat blade screwdriver Note Use a handheld screwdriver to hold down the screws at the side For RS232 RS485 serial po...

Page 16: ...and Network Type tested for 60 s 3250 V DC Output to Aux and Network Inputs to Outputs Type tested for 60 s 1950 V DC Input to Aux and Network 50V continuous Reinforced Insulation Type I O to Aux and...

Page 17: ...bit 2 5 mV count Smoothing None Input time constant typical 0 44 ms Isolation None Accuracy 25 55 C 5 of full scale 2 with calibration AC Input Specifications for I 04 I 11 for 2080 LC20 20AWB R Attr...

Page 18: ...C 86 F Off state voltage max 5V DC Off state current max 0 5 mA 1 5 mA On state current min 0 75 mA 10 8V DC 1 0 mA 15V DC 1 8 mA 10 8V DC 2 7 mA 15V DC On state current nom 2 1 mA 24V DC 8 5 mA 24V D...

Page 19: ...with no output capacitance max 20 ms Channel to bus isolation No isolation Channel to channel isolation No isolation DC Output Specifications for 2080 LC20 20QBB R Attribute Standard Outputs Outputs O...

Page 20: ...certain frequency for example the user sets frequency to 20 KHz and sets duty cycle to 30 in Connected Components Workbench then actual duty cycle is Controller current max total 3 A Turn on time max...

Page 21: ...d Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock 20 65 C 4 149 F Temperature surrounding air max 65 C 149 F Temperature nonoperating IEC 60068 2 1 Test Ab Unpackaged Nonoperating Co...

Page 22: ...trol Equipment certified for US and Canada See UL File E322657 UL Listed for Class I Division 2 Group A B C D Hazardous Locations certified for U S and Canada See UL File E334470 CE European Union 200...

Page 23: ...Micro820 20 Point Programmable Controllers 23 Publication 2080 IN009B EN P April 2014 Notes...

Page 24: ...roduct up and running New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if yo...