Over time, the backlight for the 6185-A Flat Panel Monitor will wear
out. The backlights typically last 25,000 hours before they reach 50% of
their original intensity or fail. Replacement backlights are available from
Rockwell Automation.

After you order and receive replacement backlights from Rockwell
Automation, follow the instructions included with the backlights.

Replacing the Backlight

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for Industrial 10.4" Flat Panel Monitor

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...Industrial 10 4 Flat Panel Monitor Bulletin 6185 A Installation and User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 3: ...or applying this equipment must satisfy themselves that each intended application of this equipment is acceptable In no event will Rockwell Automation be responsible or liable for indirect or conseque...

Page 4: ...140 H viewing angle NEMA 4 12 or 4X panel Touchscreen options AC 85 264V or DC 24V inputs Plug and Play ATTENTION The equipment described in this document generates uses and emits radio frequency ene...

Page 5: ...optional Video cable optional This user manual A 6185 A Flat Panel Monitor with a touchscreen option is shipped with these additional items Supporting software and manuals RS 232 serial extension cab...

Page 6: ...for cooling Never allow air passages to become obstructed Ensure that the ambient air temperature will not exceed the specified maximum temperature A user supplied fan heat exchanger or air conditione...

Page 7: ...through the AC power cord can help reduce the likelihood of static discharges which may cause shocks and damage electronic components When properly installed the 6185 A Flat Panel Monitor is designed...

Page 8: ...l cuttings do not enter any components that are already installed in the panel Supporting panels should be at least 14 gauge to ensure proper sealing against water and dust and to provide proper suppo...

Page 9: ...on 6185 5 0 Dimensions This section provides diagrams you need to follow to install the unit Figure 2 Dimensions Front View Figure 3 Dimensions Side View Artisan Technology Group Quality Instrumentati...

Page 10: ...Industrial 10 4 Flat Panel Monitor 9 Publication 6185 5 0 Figure 4 Dimensions Back View Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 11: ...to the side of the monitor is not available following installation attach the power and video cables to the side of the monitor at this time 3 Install the monitor in the prepared cutout Refer to the...

Page 12: ...must be tightened to a torque of 24 inch pounds to provide panel seal and avoid potential damage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equ...

Page 13: ...host touchscreen control port DB 9 connector optional Connecting to AC power IEC connector or DC power terminal block Note Some connectors on your monitor may differ from the following figure The fol...

Page 14: ...Touchscreen Interface The serial touchscreen interface connection to the host is made through an RS 232 DB 9 female connector located on the side panel The optional touchscreen provides a high resolu...

Page 15: ...ION Chassis ground must be connected for safe operation of the monitor The AC receptacle on the monitor is a 3 wire type with chassis ground pin and the mating AC cord supplied is a 3 wire type design...

Page 16: ...h ground The ground terminal is an M5 screw ATTENTION Chassis ground must be connected for safe operation of the monitor The DC screw terminals on the monitor have a chassis ground pin However some DC...

Page 17: ...ents to these settings to ensure that the screen image on the flat panel monitor is set up correctly If the horizontal or vertical position of the display is not adjusted correctly one edge of the scr...

Page 18: ...hold the H button on the back panel of the monitor until both the Display Active Indicator green and the Fault Indicator red begin to blink at the same time 2 Use the and buttons to adjust the horizon...

Page 19: ...e clock phase of the monitor to match the video clock rate Adjust the control until the screen image is sharp and there is no screen jitter The change should be most apparent in the vertical lines of...

Page 20: ...e describes the functions assigned to the default LED which is a single light that can be green amber or red Table A Power Indicator LED LED Color Indication Green solid Normal operation Amber solid P...

Page 21: ...s equipped with eight user controls and two LED indicators on the rear panel Note For more information on adjusting controls to achieve the best screen image refer to Page 16 Figure 8 Controls on Back...

Page 22: ...ical video framing mode Horizontal Size Position H Activates the horizontal video framing mode or the video frame width Function 1 Adjustment in the video framing mode or video frame width Function 2...

Page 23: ...dry Special care should be taken when cleaning a touchscreen or polycarbonate shield that is installed over the screen Abrasive and certain chemical cleaners can easily damage the surface Never use a...

Page 24: ...g to another monitor that is known to be operational Fault in monitor Have monitor serviced Image is not centered Position controls are not properly adjusted Reset the horizontal and vertical position...

Page 25: ...ed on the host computer to handle communications with the touch controller over the channel Because the touchscreen emulates a mouse there may be compatibility issues involving how the touchscreen emu...

Page 26: ...following information about the host hardware The COM port in use for the touchscreen Ensure that the RS 232 cable is properly installed between the monitor port and the host s COM port The baud rate...

Page 27: ...our Internet browser www elotouch com for resistive touchscreens www microtouch com for capacitive touchscreens After installing the driver software follow the instructions in the touchscreen document...

Page 28: ...ector The following table provides the pin numbers and corresponding pin assignments for the HD 15 video connector with the DDC2B capability Table D Standard HD 15 Video Cable Monitor HD 15 Female Sig...

Page 29: ...cklights typically last 25 000 hours before they reach 50 of their original intensity or fail Replacement backlights are available from Rockwell Automation After you order and receive replacement back...

Page 30: ...Video Supported Standards 640x400 at 70 Hz VGA text 640x480 at 60Hz native Video Input Signal RGB analog white level 0 714V above ref Black into 75 Ohms Sync Input Signals H and V separate TTL levels...

Page 31: ...e 20 0K VDC Operating Shock 10g 1 2 sine 11msec Non Operating Shock 30g 1 2 sine 11msec Operating Vibration 0 006in p p 10 57Hz 1 0g peak 57 640Hz sine Non Operating Vibration 0 006in p p 10 57Hz 1 0g...

Page 32: ...ombia Costa Rica Croatia Cyprus Czech Republic Denmark Dominican Republic Ecuador Egypt El Salvador Finland France Germany Ghana Greece Guatemala Honduras Hong Kong Hungary Iceland India Indonesia Ira...

Page 33: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: