background image

Power, Control and Information Solutions Headquarters

Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444

Europe/Middle East/Africa: Rockwell Automation NV, Pegasus Park, De Kleetlaan 12a, 1831 Diegem, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640

Asia P

acific: Rockw

ell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846

www.rockwel lauto

m

ation.co

m

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its 
products. At 

http://www.rockwellautomation.com/support/

, you can find technical manuals, 

a knowledge base of FAQs, technical and application notes, sample code and links to software 
service packs, and a MySupport feature that you can customize to make the best use of these 
tools.

For an additional level of technical phone support for installation, configuration and 
troubleshooting, we offer TechConnect support programs. For more information, contact 
your local distributor or Rockwell Automation representative, or visit 

http://www.rockwellautomation.com/support/

Installation Assistance

If you experience a problem within the first 24 hours of installation, please review the 
information provided in this manual. You can also contact a special Customer Support 
number for initial help in getting your product up and running.

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when 
shipped from the manufacturing facility. However, if your product is not functioning and 
needs to be returned, follow these procedures.

Documentation Feedback

Please forward us your comments and suggestions using form 

RA-DU002

United States or 
Canada

1.440.646.3434

Outside United States 
or Canada

Use the Worldwide Locator at 

http://www.rockwellautomation.com/support/

 or contact your 

local Rockwell Automation representative.

United States

Contact your distributor. You must provide a Customer Support 
case number (call the phone number above to obtain one) to your 
distributor to complete the return process.

Outside United States

Please contact your local Rockwell Automation representative for 
the return procedure.

Publication 440R-IN078A-EN-P - January 2014

Copyright © 2014 Rockwell Automation, Inc. All rights reserved.

Allen-Bradley and Rockwell Automation are trademarks of Rockwell Automation, Inc. Guardmaster is a registered trademark of 
Rockwell Automation, Inc. EtherNet/IP is a trademark of ODVA.

Trademarks not belonging to Rockwell Automation are property of their respective companies.

Summary of Contents for Guardmaster EtherNet/IP 440R-ENETR

Page 1: ...ic Page Important User Information 2 Environment and Enclosure 3 Preventing Electrostatic Discharge 4 About the Interface 5 Before You Begin 6 Determine Compatibility 6 Install the Interface 6 Set the...

Page 2: ...ciated with any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell A...

Page 3: ...esigned to prevent personal injury resulting from accessibility to live parts The enclosure must have suitable flame retardant properties to prevent or minimize the spread of flame complying with a fl...

Page 4: ...these guidelines when you handle this equipment Touch a grounded object to discharge potential static Wear an approved grounding wrist strap Do not touch connectors or pins on component boards Do not...

Page 5: ...s interface is designed for the Guardmaster safety relay optical bus that provides connectivity to an EtherNet IP network with two RJ 45 connectors for two port pass through to support daisy chain or...

Page 6: ...are 440R D22R2 GSR DI 440R D22S2 GSR DIS 440R EM4R2 GSR EM 440R EM4R2D GSR EMD 440R GL2S2P GSR GLP 440R GL2S2T GSR GLT If you use the BootP DHCP utility to assign IP addresses to the interface module...

Page 7: ...Interface on a DIN Rail Install the interface to the left of Guardmaster safety relays equipped with an optical communications bus There must be no more than 5 mm horizontal separation between two ad...

Page 8: ...Press down firmly to install the interface on a DIN rail 3 Set the network address rotary switches to the desired value See page 9 Set the Network Address for more information on setting the IP addres...

Page 9: ...etwork address by using the three rotary switches on the front bezel of the interface Use a small flat blade screwdriver to rotate the switches Line up the arrow on the switch with the number setting...

Page 10: ...Address Rotary Switches Refer to publication Guardmaster 440R UM009 EtherNet IP Network Interface User Manual for more information If you set the switches to an invalid number for example 000 or a va...

Page 11: ...as shown in the following illustration WARNING When you change switch settings while power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure...

Page 12: ...eat the interface on the DIN rail until the module locks into position 7 Set the network address on the network address rotary switches 8 Insert the removable terminal block into the interface 9 Recon...

Page 13: ...ith the CE Low Voltage Directive LVD this equipment must be powered from a Safety Extra Low Voltage SELV or Protected Extra Low Voltage PELV compliant source WARNING If you connect or disconnect wirin...

Page 14: ...Indicator Status for Interface Module Indicator Status Description Module Status Off No power applied to device Flashing green Device needs commissioning due to missing incomplete or incorrect configu...

Page 15: ...rdmaster safety relay failure and controller operation Solid red Duplicate IP address detected Verify IP address setting and correct as needed Link 1 or Link 2 Status Off No link established Solid gre...

Page 16: ...2 GSR EMD Catalog number 440R EM4R2D GSR GLP Catalog number 440R GL2S2P GSR GLT Catalog number 440R GL2S2T Location Left side of the Guardmaster Safety Relay system Power Supply Attribute Value Input...

Page 17: ...89 x 4 47 in Enclosure type rating None open style Terminal base screw torque 0 8 Nm 7 lb in Weight approx 180 g 0 4 lb Wiring category 1 1 on power ports 1 on communications ports Wire size Power co...

Page 18: ...ed Damp Heat 5 95 non condensing Vibration IEC 60068 2 6 Test Fc Operating 5 g 10 500 Hz Shock operating IEC60068 2 27 Test Ea Unpackaged Shock 15 g Emissions CISPR 11 Group 1 Class A ESD immunity IEC...

Page 19: ...2004 108 EC EMC Directive compliant with EN 61326 1 Meas Control Lab Industrial Requirements EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions EN 61131 2 Programmable Controllers Clau...

Page 20: ...24 hours of installation please review the information provided in this manual You can also contact a special Customer Support number for initial help in getting your product up and running New Produ...

Reviews: