Rockwell Automation 442G-IN001C-EN-P – October 2015
Multi-functional Access Box Installation Instructions
3
Dimensions [mm (in.)]
Electrical Connection
The electrical connections must either be isolated from the mains
supply by a safety transformer according to IEC 61558-2-6 with
limited output voltage in the event of a fault, or by other
equivalent isolation measures.
For detailed information on the electrical connection, refer to the
user manual.
Terminal Assignments and Wiring
Connection of Cover Controls and Indicators
113.5 (4.47)
104 (4.09)
40
(1.57)
40
(1.57)
15
(0.59)
33.5
(1.32)
40
(1.57)
106
(4.17)
155.3 (6.11)
130 (5.12)
4 (0.16)
114
(4.49)
111
(4.37)
83
(3.27)
<51>
(2.01)
40
(1.57)
62.5
(2.46)
M20 x 1.5 (4x)
19.2
(0.76)
289.3 (11.39)
10-45.1
(0.39-1.78)
OPEN
CL
OSED
Co
nt
ro
ls
S 1 S 2
4
S
3
S
6 (0.24)
37.5
(1.48)
1 (0.04)
21
(0.83)
30
(1.18)
19
(0.75)
60
(2.36)
47.5
(1.87)
A
minimum
maximum
Detail A
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
Terminal assignment
X5
X4
X3
optional cover function*
X2
IMM
IMP
*
0V
UA
OT
OL
OI
0V
UB
OD
6 5 4 3 2 1
FI1B
*
FO1A
FO1B
RST
FI1A
6 5 4 3 2 1
2
3
4
5
1
11
10
9
8
7
12
18
19
15
6
17
16
13
14
19-pin M23 QD
H2
1
3
S1
7
2
5 4 3
S3
H3
0V
2
X2
6
8
5
4
1
H4
S4
6
S2
A
U (24V)
X3
1
19-pin mating cordset Cat. No. 889M-F19RM-*
2
The lock modules are factory preset for standalone operation. See the user
manual for configuring the device for series operation (cable entry models only).
3
On QD models, terminal X5.6 is connected internally to terminal X3.4.
For models with E-stop and three push buttons (lock module
catalog numbers ending in –C04):
M23 QD
19-Conductor
Cordset
1
MAB Internal
Wire Color Terminal Function
Description
1
Violet
Brown
X3.7
IMP
Lock command
2
Red
Yellow
X2.1
S1.A1
E-stop circuit A
3
Grey
White
X2.2
S1.B1
E-stop circuit B
N/A
N/A
No Connection
X4.1
FI1A
Safety input channel A
2
N/A
N/A
No Connection
X4.2
FI1B
Safety input channel B
2
4
Red/Blue
Green
X4.4
FO1A
Safety output channel A, ON
when guard is locked
5
Green/Black
Grey
X4.5
FO1B
Safety output channel B, ON
when guard is locked
6
Blue
Black
X3.5
0V
Connected internally to X5.5
7
Grey/Pink
Pink
X4.6
RST
Reset, apply 24V for at least
3 seconds
8
White/Green
Violet
X5.2
OT
Bolt monitoring output, ON
when guard is closed and
bolt is extended
9
White/Yellow
Brown/Green
X5.4
OI
Fault diagnostic, ON when
the switch is in a fault state
10
White/Grey
Red/Blue
X2.3
S1.A2
E-stop circuit A
11
Black
Grey/Pink
X2.4
S1.B2
E-stop circuit B
N/A
N/A
No Connection
X2.6
S1 Aux.
E-stop monitoring contact
12
Green/Yellow
N/A
N/A
GND
Connector housing GND
13
Yellow/Brown
Grey/Brown
X2.7
S2
Push button switching
element (S2)
14
Brown/Green
White/Yellow
X3.1
H2
Push button LED (H2)
15
White
Yellow/Brown
X3.2
S3
Push button switching
element (S3)
16
Yellow
White/Grey
X3.3
H3
Push button LED (H3)
N/A
N/A
No Connection
x5.1
OD
Door monitoring output, ON
when the door is closed
17
Pink
White/Green
X5.3
OL
Lock Monitoring output, ON
when guard is locked
18
Grey/Brown
Yellow/Black
X3.8
IMM
Reserved for future use
19
Brown
Blue
X3.4
UA
Power for solenoid and
monitoring outputs
X5.6
UB
Power for safety outputs
17
Pink
White/Green
X2.5
S4
Push button non-switching
element (S4)
18
Grey/Brown
Yellow/Black
X2.8
H4
Push button LED (H4)
Connection of this device with a conduit is not allowed. The connection
method needs to consist of flexible cord that is connected to the product
with a UL Listed cable gland suitable for 22…17 AWG wire sizes (for
example, Type HSK-KM20 x 1.5 manufactured by
Hummel A
G).
IMPORTANT