Publication 1756-UM001E-EN-P - August 2002
Communicate with 1756 I/O over a ControlNet™ Network
8-13
Schedule the ControlNet
Network
A.
Download the RSLogix 5000 project to the controller.
B.
Start RSNetworx
™
for ControlNet software.
C.
Has this network been scheduled before?
If:
Then:
No
1. From the
File
menu, select
New
.
2. From the
Network
menu, select
Online
.
3. Select your ControlNet network and choose
OK
.
4. Select the
Edits Enabled
check box.
5. From the
Network
menu, select
Properties
.
6. From the
Network Parameters
tab, type or select the following parameters:
In this box:
Specify:
Network Update Time
repetitive time interval in which data is sent over the ControlNet network
Max Scheduled Address
greatest node number to use scheduled communications on the network
Max Unscheduled Address
greatest node number that you will use on the network
Media Redundancy
channels in use
Network Name
name for the network
7. Click
OK
.
8. From the
Network
menu, select
Single Pass Browse
.
9. From the
File
menu, select
Save
.
10. Type a name for the file that stores the network configuration, then click
Save
.
11. Select the
Optimize and re-write Schedule for all Connections
button (default) and click
OK
.
12. In RSLogix 5000 software, save the online project.
Yes
1. From the
File
menu, select
Open
.
2. Select the file for the network and choose
Open
.
3. From the
Network
menu, select
Online
.
4. Select the
Edits Enabled
check box.
5. From the
Network
menu, select
Properties
.
6. From the
Network Parameters
tab, update the following parameters:
In this box:
Specify:
Max Scheduled Address
greatest node number to use scheduled communications on the network
Max Unscheduled Address
greatest node number that you will use on the network
7. Click
OK
.
8. From the
Network
menu, select
Single Pass Browse
.
9. From the
File
menu, select
Save
.
10. Select the
Optimize and re-write Schedule for all Connections
button (default) and click
OK
.
11. In RSLogix 5000 software, save the online project.
Summary of Contents for controllogix 1756-L63
Page 1: ...ControlLogix System 1756 L1 L1Mx L55Mxx L63 User Manual Allen Bradley HMIs...
Page 4: ...Publication 1756 UM001E EN P August 2002 Summary of Changes 2 Notes...
Page 16: ...Publication 1756 UM001E EN P August 2002 Table of Contents x...
Page 268: ...Publication 1756 UM001E EN P August 2002 15 4 Monitor Connections Notes...
Page 276: ...Publication 1756 UM001E EN P August 2002 16 8 Communicate with a DeviceNet Device Notes...
Page 402: ...Publication 1756 UM001E EN P August 2002 24 22 Program Motion Control Notes...
Page 408: ...Publication 1756 UM001E EN P August 2002 25 6 Maintain the 1756 BA1 Battery Notes...
Page 418: ...Publication 1756 UM001E EN P August 2002 B 2 Estimate Execution Time...
Page 420: ...Publication 1756 UM001E EN P August 2002 C 2 Estimate Memory Use...
Page 422: ...Publication 1756 UM001E EN P August 2002 D 2 Determine When Data Is Updated Notes...
Page 424: ...Publication 1756 UM001E EN P August 2002 E 2 Reconfigure an I O module Notes...
Page 428: ...Publication 1756 UM001E EN P August 2002 4 Index...
Page 429: ...Publication 1756 UM001E EN P August 2002 Index 5 Allen Bradley HMIs...
Page 430: ...Publication 1756 UM001E EN P August 2002 6 Index...
Page 435: ...ControlLogix System User Manual Allen Bradley HMIs...