Important User Information

Solid state equipment has operational characteristics differing from those of electromechanical equipment. 

Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls

 (Publication 

SGI-1.1 available from your local Rockwell Automation sales office or online at 
http://www.ab.com/manuals/gi) describes some important differences between solid state equipment 
and hard-wired electromechanical devices. Because of this difference, and also because of the wide 
variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy 
themselves that each intended application of this equipment is acceptable.

In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages 
resulting from the use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the 
many variables and requirements associated with any particular installation, Rockwell Automation, Inc. 
cannot assume responsibility or liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, 
equipment, or software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell 
Automation, Inc. is prohibited.
Throughout this manual we use notes to make you aware of safety considerations.

WARNING

Identifies information about practices or circumstances that can cause an explosion in a 
hazardous environment, which may lead to personal injury or death, property damage, 
or economic loss.

IMPORTANT

Identifies information that is critical for successful application and understanding of the 
product.

ATTENTION

Identifies information about practices or circumstances that can lead to personal injury or 
death, property damage, or economic loss. Attentions help you:

identify a hazard

avoid a hazard

recognize the consequence

SHOCK HAZARD

Labels may be located on or inside the equipment to alert people that dangerous voltage 
may be present.

BURN HAZARD

Labels may be located on or inside the equipment to alert people that surfaces may be 
dangerous temperatures.

Summary of Contents for ArmorPoint DeviceNet 1738-ADN12

Page 1: ...The DeviceNet adapters are shown below DeviceNet X10 X1 Adapter Status DeviceNet Status PointBus Status System Power Adapter Power 1738 ADN18 PWR 1738 ADN18P DNet In DNet Out X1 Adapter Status Device...

Page 2: ...with any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automat...

Page 3: ...t should not require additional system enclosure when used in locations consistent with the enclosure type ratings stated in the Specifications section of this publication Subsequent sections of this...

Page 4: ...g screws ATTENTION Preventing Electrostatic Discharge This equipment is sensitive to electrostatic discharge which can cause internal damage and affect normal operation Follow these guidelines when yo...

Page 5: ...Manager or another software configuration tool Setting the switches at any number from 64 through 99 lets the software have address control Each module is shipped with the switches set for node addres...

Page 6: ...cur which is indicated by a flashing red Adapter Status LED Settings of 64 through 99 cause the module to use the last valid node address stored internally Example The last setting internally was 40 I...

Page 7: ...nnections against leaks and maintain IP67 requirements view into connector Pin 1 Drain Pin 2 V Pin 3 V Pin 4 CAN_High Pin 5 CAN_Low 43764 Male In Connector Female Out Connector 1738 ADN12 Subnet out 1...

Page 8: ...y Flashing Red Recoverable fault Red Unrecoverable fault may require device replacement Flashing Red Green Device is in self test DeviceNet Status Off Device is not on line Device attempting to AutoBa...

Page 9: ...evice the device has detected a network access error and is in communication faulted state Device has received and accepted an Identify Communication Faulted Request long protocol message PointBus Sta...

Page 10: ...on Power Supply The 1738 EP24DC can supply up to an additional 1 3A of backplane current Multiple 1738 EP24DC modules can be used to reach the maximum of 63 modules Cat No PointBus Current Requirement...

Page 11: ...er single fault conditions A PELV supply has the same rating and is connected to protected earth Input Voltage Rating 24V dc 10 28 8V dc range Input Overvoltage Protection Reverse polarity protected I...

Page 12: ...on shielded ports Conducted RF Immunity IEC 61000 4 6 10Vrms with 1kHz sine wave 80 AM from 150kHz to 80MHz Emissions CSPR 11 Group 1 Class A Enclosure Type Rating Meets IP65 66 67 when marked Mountin...

Page 13: ...Publication 1738 IN014A EN E June 2004 ArmorPoint DeviceNet Adapters Series A 13 Notes Allen Bradley Drives...

Page 14: ...e module within the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your...