Allen-Bradley ArmorBlock 1732E-16CFGM12M12LDR User Manua Download Page 5

Rockwell Automation Publication 1732E-UM001A-EN-P - December 2019

5

Preface

This manual describes how to use the ArmorBlock® I/O 16-channel configurable 
digital module.

Make sure that you are familiar with the following:

• Use of a controller in a Logix 5000™ control system
• Studio 5000 Logix Designer® environment

Who Should Use This 
Manual

This manual is intended for trained and qualified personnel who are responsible 
for mounting, installation, commissioning, operation, maintenance, and 
disassembly of the ArmorBlock I/O 16-channel configurable digital module.

Purpose of This Manual

This manual provides information and describes the procedures that are used to 
install, wire, troubleshoot, and operate the ArmorBlock I/O 16-channel 
configurable digital module.

Additional Resources

These resources contain information about related products from 
Rockwell Automation.

You can view or download publications at 

https://www.rockwellautomation.com/literature/

. For publications specific to 

your module, search the catalog number of the module. To order paper copies of 
technical documentation, contact your local Allen-Bradley distributor or 
Rockwell Automation sales representative.

IMPORTANT

You must use the RSLogix 5000® and Studio 5000®, version 20.00.00 or later, to 
configure the ArmorBlock I/O module.

Resource

Description

ArmorBlock I/O 16-Channel Configurable Digital Module 
Installation Instructions, publication 

1732E-IN008

 

Describes how to install and wire the ArmorBlock I/O 
module.

ArmorBlock I/O Selection Guide, publication 

1732-SG001

 

Provides specifications, wiring diagrams, and module 
block diagrams for ArmorBlock I/O modules.

Industrial Automation Wiring and Grounding Guidelines, 
publicatio

1770-4.1

 

Provides general guidelines for installing a 
Rockwell Automation industrial system

Product Certifications website,

https://www.rockwellautomation.com/
rockwellautomation/certification/overview.page

 

Provides declarations of conformity, certificates, and other 
certification details.

Summary of Contents for ArmorBlock 1732E-16CFGM12M12LDR

Page 1: ...ArmorBlock 16 Channel Configurable Digital Module Catalog Numbers 1732E 16CFGM12M12LDR 1732E 16CFGM12P5DR User Manual OriginalInstructions...

Page 2: ...information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited...

Page 3: ...eters 12 Output Fault Delay Configuration 13 Configure QuickConnect 13 Configure General Parameters 14 Configure Process Data Direction 15 Configure in Logix Designer 15 Initial Settings of the Connec...

Page 4: ...Diagnostic Properties Channel Error 35 Voltage Errors at M12 Slots Sensor Short circuit 36 Overload of Output Drivers 36 Error in Actuator Power Supply 36 Error in System Sensor Power Supply 37 Append...

Page 5: ...nload publications at https www rockwellautomation com literature For publications specific to your module search the catalog number of the module To order paper copies of technical documentation cont...

Page 6: ...6 Rockwell Automation Publication 1732E UM001A EN P December 2019 Preface Notes...

Page 7: ...ing power the 1732E 16CFGM12M12LDR uses M12 L coded connectors while the 1732E 16CFGM12P5DR uses 7 8 inch connectors Module Features The ArmorBlock 16 channel configurable digital module provides the...

Page 8: ...figurable Digital Module module installation instructions publication 1732E IN008 for instructions on how to install the modules MAC XX XX XX XX XX XX M12 style A coded I O connectors Functional earth...

Page 9: ...llautomation com Pages home aspx After you have downloaded the EDS file you must register it using the EDS hardware installation tool To register the EDS file do the following 1 In Studio 5000 Logix D...

Page 10: ...Browse and select the EDS file that you have downloaded 5 Click Next to begin the EDS file registration 6 Verify that the EDS Wizard successfully completed the registration 7 Click Finish Read the MAC...

Page 11: ...ernatively you can reset the rotary switches and use BOOTP or DHCP to obtain the network parameters for the module If you change the operating mode or network parameters during operation you must cycl...

Page 12: ...object you can decide how many items of I O process data the module makes available to the user The ArmorBlock I O 16 channel configurable digital module provides the following connections and assembl...

Page 13: ...you enable QC the module accepts a TCP connection and the control system establishes a connection within 350 ms after being switched on The module can achieve a total start up time of 400 500 ms To us...

Page 14: ...s Bit MSB LSB 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Word 32 QuickConnect Where 0 Disabled default 1 Enabled Table 5 General Parameters Parameter Description WebServerDisable Enables or disables the we...

Page 15: ...to install the EDS files for the module 6 Right click on the EtherNet IP communication interface and select New Module The Select Module Type dialog appears 7 Select the EtherNet IP module and click...

Page 16: ...de a list of useful parameters Edit the Module Configuration Common Pages Click a page name in the New Module dialog box to view and edit the parameters available for that page General Page Connection...

Page 17: ...of General Page Table 9 General Parameters Parameter Definition Type Type of module Vendor Rockwell Automation Allen Bradley Name Enter a name for the module Description Enter an optional description...

Page 18: ...Parameter Definition Series Module hardware series Revision Module firmware revision including major and minor revision levels Electronic Keying Software method by which you reduce the possibility of...

Page 19: ...he type of connection Requested Packet Interval RPI ms Set the RPI rate Connection over EtherNet IP Set the type of connection to use on the EtherNet IP network Inhibit Module Select to inhibit the mo...

Page 20: ...the connection is uninhibited In your application a controller already owns a module has downloaded the configuration to the module and is exchanging data over the connection between the devices In t...

Page 21: ...uick Connect can help to reduce connection times if the module if used in a system where it has to be connected and disconnected as part of normal operation Figure 5 Example of Quick Connect Page Tabl...

Page 22: ...Fault Displays the fault code if a major fault occurs Minor Fault Displays the fault code if a minor fault occurs Internal State Displays the current operational state of the module Configured ForI Om...

Page 23: ...esh the data on the page Reset Module Reset the module to factory settings Table 14 Fault Program Action Parameters Parameter Definition Output State During Fault Program Mode Off On Hold IMPORTANT Do...

Page 24: ...ay from 0 255 ms Default is 80 ms Data Direction Set whether the direction of datais input only output only or both input and output You cannot change the data direction when the module is online Disa...

Page 25: ...d to configure the IP settings manually Figure 9 Example of Internet Protocol Page Table 16 Internet Protocol Parameters Parameter Definition Physical Module IP Address Assign the addresses forthe mod...

Page 26: ...ion Parameters Parameter Definition Enable Select to enable the port Link Status Displays the connection status of the port Auto Negotiate Select to enable auto negotiate for the port Speed Selected S...

Page 27: ...work that the module is connected to Figure 11 Example of Network Page Table 18 Network Parameters Parameter Definition Network Mode Displays the currently selected network redundancy protocol Network...

Page 28: ...28 Rockwell Automation Publication 1732E UM001A EN P December 2019 Chapter 2 Configure and Startup Notes...

Page 29: ...ister the EDS files see Download and Register EDS File on page 9 For EtherNet IP modules the input data are given as actual values and the output data as target values The amount of input data is vari...

Page 30: ...hapter 3 Configure Module Using Generic Profile Configure the Module as a Generic Device To configure the module as a generic device follow these steps 1 Add the module as a generic Ethernet module 2...

Page 31: ...it 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 C7 C6 C5 C4 C3 C2 C1 C0 Byte 1 C15 C14 C13 C12 C11 C10 C9 C8 Byte 2 InternalFault 0 0 0 OutputGroupFault InputGroupFault FieldPowerLow PowerFault Byte 3...

Page 32: ...putGroupPowerFaultEn BIT OutputGroupFaultEn BIT DOAutoRestartEn Bit Pt00DataDirection Pt15DataDirection INT Pt00IOMapping Pt15IOMapping INT Table 19 Description ofTerms in Process DataTables Parameter...

Page 33: ...ion In this case PowerFault signifies that sensor power supply voltage is less than 18V For a list of tag functions available for the module see Description of Terms in Process Data Tables on page 32...

Page 34: ...34 Rockwell Automation Publication 1732E UM001A EN P December 2019 Chapter 3 Configure Module Using Generic Profile Notes...

Page 35: ...at M12 Slots Sensor Short circuit 36 Overload of Output Drivers 36 Error in Actuator Power Supply 36 Error in System Sensor Power Supply 36 Table 20 Description of Channel Errors TargetValue ActualVa...

Page 36: ...ad This error is reported by setting the relevant channel error bits in the diagnostic bytes If there is an overload the status indicator of the active output channel lights up red If both output chan...

Page 37: ...no effect on the outputs and is not filtered but is reported immediately ATTENTION Every output channel that is active at the same time as the error occurs in supply voltage UL is locked This means t...

Page 38: ...38 Rockwell Automation Publication 1732E UM001A EN P December 2019 Chapter 4 Diagnostic Properties Notes...

Page 39: ...tors Figure 12 Status Indicators Topic Page Status Indicator Overview 39 Status Indicator Descriptions 40 MAC XX XX XX XX XX XX MAC XX XX XX XX XX XX Channel status indicators 1732E 16CFGM12M12LDR 173...

Page 40: ...Module ready for operation Flashing red Recoverable fault An incorrect or contradictory configuration is classified as a recoverable fault Red Non recoverable fault Flashing red green Module is perfor...

Page 41: ......

Page 42: ...al support engineer https www rockwellautomation com global support direct dial page Literature Library Installation Instructions Manuals Brochures and Technical Data https www rockwellautomation com...

Reviews: