Mounting Dimensions [mm]

Contact Opening Characteristics

Wiring Diagram

Nonpanel Mount

Panel Mount

Dome 
Plunger

Cross Roller Plunger

Bottom Cable Style

32.2

(1.27)

35.0

(1.37)

43.0

(1.69)

6.10

(2.40)

Replacement Switch, without 

a Lever (440P-NX10)

Roller Plunger

Countersink Hole

\

• Panel mount clearance hole = 13 mm (0.51 in.) max.

Maintenance

These devices require little maintenance, but routine visual 
inspection is recommended to keep foreign debris from 
collecting on the exterior actuators and rollers. Removing the 
operator head is not recommended as loose internal components 
may be lost or improperly re-installed.

Actuation Guidelines

The method of actuation and over travel has significant influence 
on the service life of the limit switch. To maximize the service life, 
it is recommended to provide an actuator with a 30° pressure 
angle and a surface hardness of Rc-45 max.

Lever Positioning

Some rotary switches are supplied with levers that are 
mechanically coupled to the actuating shaft. The lever may be 
removed and re-installed to adjust cam tracking. See table below 
for torque recommendations.

Torque Specifications

Location

Torque

3.5 mm Operator Head Phillips Screws

0.8 N•m (7.1 lb•in)

Short and Wide Roller Lever A rm

8 mm Hex Nut

1.0 N•m (8.85 lb•in)

Adjustable Lever Arm

4 mm Allen Head Screw

1.8…2.8 N•m

(15.93…24.78 lb•in)

Adjustable Lever Arm Collar

3 mm Allen Head Screw

3.2 N•m (28.32 lb•in)

12 mm Panel Mount Nut

1.5 N•m (13.28 lb•in)

ATTENTION

Under no circumstances must the switch be actuated beyond 
the mechanical travel specified. Serious damage to the device 
and property could result.