Rockwell Automation Publication 23PFC-TG001A-EN-P - March 2018
87
Frame B Field Controller Part Replacement Procedures
Chapter 4
115V AC to 24V DC I/O
Converter Circuit Board
Replacement
Remove the 115V AC to 24V DC I/O Converter Circuit Board
1. Read the General Safety Precautions on page
2. Remove power from the device (see page
3. Remove the protective covers from the device (see page
4. Remove the plug-in I/O terminal blocks with the wiring kept in place.
5. Remove the two M3 x 6 mm screws and washers that secure the I/O
converter board to the stand-offs on the control board and remove the
I/O converter board.
6. Remove the two stand-offs from the control board.
IMPORTANT
Mark all connections and wires before removal to avoid incorrect
wiring during reassembly.
=
5
Torque Specification:
1.0 N•m (8.9 lb•in)
6
Torque Specification:
1.0 N•m (8.9 lb•in)