Allen-Bradley 22A-A1P5N104 Quick Start Manual Download Page 12

English-12

Dimensions are in millimeters and (inches). Weights are in kilograms and (pounds).

PowerFlex 4 Frames

 – Ratings are in kW and (HP) 

Optional Conduit Box

 – Dimensions are in millimeters and (inches)

Publication 22A-QS001B-EN-P – May 2002

Supersedes December 2001

Copyright © 2002 Rockwell Automation, Inc. All rights reserved. Printed in Taiwan.

Drive Dimensions

A

G E

D

C

B

F

5.5 (0.22)

Frame

A

B

(1)

C

D

E

(2)

F

G

Shipping 
Weight

A

80 (3.15)

185 (7.28)

136 (5.35)

67 (2.64)

152 (5.98)

59.3 (2.33)

140 (5.51)

1.4 (3.1)

B

100 (3.94)

213 (8.39)

136 (5.35)

87 (3.43)

180 (7.09)

87.4 (3.44)

168 (6.61)

2.2 (4.9)

(1)

Overall height of drive with IP 30/NEMA 1/UL Type 1 option kit installed.

(2)

Overall height of standard IP 20/Open Type drive.

Frame

120V AC – 1-Phase

240V AC – 1-Phase

240V AC – 3-Phase

480V AC – 3-Phase

A

0.2 (0.25)
0.37(0.5)

0.2 (0.25)
0.37 (0.5)
0.75 (1.0)

0.2 (0.25)
0.37 (0.5)
0.75 (1.0)
1.5 (2.0)

0.37 (0.5)
0.75 (1.0)
1.5 (2.0)

B

0.75(1.0)

1.5 (2.0)

2.2 (3.0)
3.7 (5.0)

2.2 (3.0)
3.7 (5.0)

59.2

(2.33)

40.0

(1.57)

20.7

(0.81)

75.3

(2.96)

34.0

(1.34)

74.3

(2.93)

35.6

(1.40)

64.1

(2.52)

79.1

(3.11)

40.6

(1.60)

25.6

(1.01)

∅ 

22.2

 (0.88)

∅ 

22.2

 (0.88)

Frame A

Frame B

U.S. Allen-Bradley Drives Technical Support

Tel: (1) 262.512.8176, Fax: (1) 262.512.2222, Email: [email protected], Online: www.ab.com/support/abdrives

Summary of Contents for 22A-A1P5N104

Page 1: ...ry may result if this parameter A092 Auto Rstrt Tries A094 Start At PowerUp is used in an inappropriate application Do not use this function without considering applicable local national and internati...

Page 2: ...747 in m4 x 0 7 8 32 1 56 1 96 Nm 14 17 lb in AmbientTemperature Enclosure Rating Minimum Mounting Clearances Minimum Maximum 10 C 14 F 40 C 104 F IP 20 Open Type Use Mounting Option A IP 30 NEMA 1 UL...

Page 3: ...0 240 Hz Programmable Efficiency 97 5 Typical Digital Control Inputs Input Current 6mA Analog Control Inputs SRC Source Mode 18 24V ON 0 6V OFF SNK Sink Mode 0 6V ON 18 24V OFF 4 20mA Analog 250 ohm...

Page 4: ...pt these are not recommendations Input Power Condition Corrective Action Low Line Impedance less than 1 line reactance Install Line Reactor 2 or Isolation Transformer Greater than 120 kVA supply trans...

Page 5: ...pply input impedance 250 ohm P038 16 RS485 DSI Shield Terminal should be connected to safety ground PE when using the RS485 DSI communications port 3 Only one analog frequency source may be connected...

Page 6: ...ures see next page before setting any Program Group parameters Start Stop Direction and Speed Control Factory default parameter values allow the drive to be controlled from the integral keypad No prog...

Page 7: ...pe Back one step in programming menu Cancel a change to a parameter value and exit Program Mode Select Advance one step in programming menu Select a digit when viewing parameter value Up Arrow Down Ar...

Page 8: ...w to scroll through the parameters that are in the group 7 Press Enter or Sel to view the value of a parameter If you do not want to edit the value press Esc to return to the parameter number 8 Press...

Page 9: ...ource is set for 3 Wire control When in three wire control I O Terminal 01 is controlled by P037 Stop Mode 1 Stop input also clears active fault P038 Speed Reference 0 5 0 Drive Potentiometer 1 Intern...

Page 10: ...Disabled 1 Electrical 2 Mechanical 3 Both 1 A098 SW Current Trip 0 0 Drive Amps 2 0 1 Amps 0 0 Disabled A099 Process Factor 0 1 999 9 0 1 30 0 A100 Fault Clear 0 2 0 Ready 1 Reset Active Fault 2 Clear...

Page 11: ...the current set by parameter A089 Current Limit F7 Motor Overload 1 An excessive motor load exists Reduce load so drive output current does not exceed the current set by parameter P033 Motor OL Curren...

Page 12: ...36 5 35 87 3 43 180 7 09 87 4 3 44 168 6 61 2 2 4 9 1 Overall height of drive with IP 30 NEMA 1 UL Type 1 option kit installed 2 Overall height of standard IP 20 Open Type drive Frame 120V AC 1 Phase...