Allen-Bradley 2080-LC50-48AWB Installation Instructions Manual Download Page 20

Rockwell Automation Support

Rockwell Automation provides technical information on the Web to assist you in using its 
products. At 

http://support.rockwellautomation.com

, you can find technical manuals, a 

knowledge base of FAQs, technical and application notes, sample code and links to software 
service packs, and a MySupport feature that you can customize to make the best use of these 
tools.

For an additional level of technical phone support for installation, configuration and 
troubleshooting, we offer TechConnect support programs. For more information, contact your 
local distributor or Rockwell Automation representative, or visit 

http://support.rockwellautomation.com

.

Installation Assistance

If you experience a problem within the first 24 hours of installation, please review the 
information that's contained in this manual. You can also contact a special Customer Support 
number for initial help in getting your product up and running.

New Product Satisfaction Return

Rockwell Automation tests all of its products to ensure that they are fully operational when 
shipped from the manufacturing facility. However, if your product is not functioning and needs 
to be returned, follow these procedures.

Allen-Bradley, Rockwell Automation, Micro800, Micro830, Micro850, and TechConnect are trademarks of Rockwell Automation, Inc. 
Trademarks not belonging to Rockwell Automation are property of their respective companies.

United States

1.440.646.3434
Monday – Friday, 8 a.m. – 5 p.m. EST

Outside United 
States

Please contact your local Rockwell Automation representative for any 
technical support issues.

United States

Contact your distributor. You must provide a Customer Support case number 
(call the phone number above to obtain one) to your distributor in order to 
complete the return process.

Outside United 
States

Please contact your local Rockwell Automation representative for the return 
procedure.

Publication 2080-IN008C-EN-P - August 2017

                                                      PN-458219

Supersedes Publication 2080-IN008B-EN-P - April 2014

Copyright © 2017 Rockwell Automation, Inc. All rights reserved. Printed in Singapore.

Rockwell Automation maintains current product environmental information on its website at

http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page

.

Summary of Contents for 2080-LC50-48AWB

Page 1: ...em portugu s como PDF V ao endere o web que aparece acima para encontrar e fazer download da publica o IT Questa pubblicazione disponibile in Italiano in formato PDF Per scaricarla collegarsi al sito...

Page 2: ...llation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to us...

Page 3: ...rating of 5VA or be approved for the application if nonmetallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain addition...

Page 4: ...sque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature global du sys...

Page 5: ...to this module or any device on the USB network an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous...

Page 6: ...returned to the manufacturer for repair Do not dismantle the module ATTENTION To comply with the CE Low Voltage Directive LVD this equipment must be powered from a source compliant with the following...

Page 7: ...eful when stripping wires Wire fragments that fall into the controller could cause damage Once wiring is complete make sure the controller is free of all metal fragments Resource Description Micro830...

Page 8: ...ntroller Overview Controller Description Description Description 1 Status indicators 9 Expansion I O slot cover 2 Optional power supply slot 10 DIN rail mounting latch 3 Plug in latch 11 Mode switch 4...

Page 9: ...and other sources of electrical noise such as hard contact switches relays and AC motor drives For more information on proper grounding guidelines see the Industrial Automation Wiring and Grounding G...

Page 10: ...il the controller snaps onto the DIN rail 2 Push the DIN rail latch back into the latched position Use DIN rail end anchors Allen Bradley part number 1492 EA35 or 1492 EAHJ35 for vibration or shock en...

Page 11: ...cross the coil of an inductive device you prolong the life of the output or relay contacts You also reduce the effects of voltage transients and electrical noise from radiating into adjacent systems R...

Page 12: ...O 09 O 07 O 10 O 11 CM8 O 12 O 14 O 13 CM9 O 15 1 2 3 4 5 6 7 8 9 10 11 12 O 05 CM5 O 06 CM6 13 14 15 16 O 17 O 16 O 19 O 18 13 14 15 16 45039 Input Terminal Block Output Terminal Block I 00 COM0 I 0...

Page 13: ...er Capacitance and Inductance Values table Capacitance and Inductance Values Nonincendive Equipment Associated Apparatus Vmax or Ui Voc or Vt or Uo Imax or Li Isc or It or Io Ci Ccable Ca or Co Li Lca...

Page 14: ...driver Input circuit type 120V AC 12 24V sink source standard 24V sink source high speed Output circuit type Relay 24V DC sink standard and high speed 24V DC source standard and high speed Power consu...

Page 15: ...on Type Output to Aux and Network Inputs to Outputs Type tested for 60 s 3250V DC Output to Aux and Network Inputs to Outputs 50V continuous Reinforced Insulation Type Input to Aux and Network Type te...

Page 16: ...2 reinforced insulation Voltage category 110V AC 12 24V sink source standard 24V sink source high speed Operating voltage range 132V 60Hz AC max 16 8 26 4V DC 65 C 149 F 16 8 30 0V DC 30 C 86 F 10 26...

Page 17: ...rrent continuous max 2 0 A 100 mA high speed operation 1 0 A 30 C 0 3 A 65 C standard operation 1 0 A 30 C 0 3 A 65 C standard operation Surge current per point See Relay Contacts Ratings on page 17 4...

Page 18: ...500 Hz Shock operating IEC 60068 2 27 Test Ea Unpackaged Shock 25 g Shock non operating IEC 60068 2 27 Test Ea Unpackaged Shock DIN mount 25 g PANEL mount 35 g Emissions IEC 61000 6 4 ESD immunity IE...

Page 19: ...rs Clause 8 Zone A B European Union 2014 35 EU LVD compliant with EN 61131 2 Programmable Controllers Clause 11 European Union 2011 65 EU RoHS compliant with EN 50581 Technical documentation RCM Austr...

Page 20: ...fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures Allen Bradley Rockwell Automation Micro800 Mi...

Reviews: