Communication Interface Module
Cat. No. 1784KT/B
Installation Data
8
Table C
Recommended interrupt settings
Equipment:
Preferred Interrupt:
1784T35
IRQ5
1784T50
IRQ5
T53 Industrial
Programming Terminal
no interrupt
T60 Industrial
Workstations
T70 Industrial
Workstations
8.
Set the memory location address, by pushing the switches in at either
the top or bottom, to reflect the selected address of the memory
location.
Interrupt Jumper
(shown in no interrupt"
position)
Address Switch
(shown at D400:0000 setting)
Up = 0
switch pressed
in at
top
Down = 1
switch pressed
in at
bottom