Allen-Bradley 1771-OWN Installation Instructions Manual Download Page 8

Specifications

  8

Selectable Contact Output Module Cat. No. 1771-OWN

Publication 17715.37 - October 1995

Outputs per module

32 (4 groups of 8)

Module Location

1771A1B thru A4B or later, 1771AM, AM1  I/O Chassis

Voltage Rating

24  138V ac rms; 24  125V dc

Current Rating

1

Max. per channel

Max. per module

Max. per group

1A continuous (derate linearly 0.033A/

o

C above 45

o

C)

12A (derate linearly 0.4A/

o

C above 45

o

C)

4A (derate linearly 0.133A/

o

C above 45

o

C)

Surge Current

1A (max) per output (at rated power)

2

Power Rating

dc: 30W per output (resistive) maximum

ac: 30W per output (resistive) maximum

Minimum Contact Load

10mA

Operate/Release Time

5ms (+1ms) typical

Bounce Time

1ms (max)

Switching Frequency

10Hz (max)

Power Dissipation

All relays off: 15mW; All relays on: 12.5W (max.)

Thermal Dissipation

All relays off: 0.05 BTU/hr; All relays on: 42.75 BTU/hr (max.)

Backplane Current

2.5A maximum; 1.8A nominal

Isolation Voltage

Isolation meets or exceeds UL Standard 508, and CSA Standard

C22.2 No. 142.

Interconnect Cable Length

1000 ft. (304.8 meters)

Conductors Wire Size

Category

14 gauge (2mm

2

) stranded (max)

3/64 inch (1.2mm) insulation (max)

1

3

Environmental Conditions

Operational Temperature

Storage Temperature

Relative Humidity

0 to 60

o

C (32 to 140

o

F)

40 to 85

o

C (40 to 185

o

F)

5 to 95% (without condensation)

Keying

Between 6 and 8 and Between 16 and 18

Field Wiring Arm

1771WN

Wiring Arm Screw Torque

79 inchpounds

Agency Certification

(when product or packaging is marked)

CSA certified

CSA Class I, Division 2, Groups A, B, C, D certified

UL listed

CE marked for all applicable directives

1

 Spikes, peaks and surges must be within the power rating. Resistive loads only. ac and dc power = 30W max.

2

 Surge limiting circuitry is not provided in the module. For reliable operation, the user must ensure that surges do not exceed either the voltage or

current rating of the module.

You use this conductor category information for planning conductor routing as described in the systemlevel installation manual.

AllenBradley, a Rockwell Automation Business, has been helping its customers improve

productivity and quality for more than 90 years. We design, manufacture and support a broad

range of automation products worldwide. They include logic processors, power and motion

control devices, operator interfaces, sensors and a variety of software. Rockwell is one of the

world's leading technology companies.

Worldwide representation.

Argentina 

 Australia 

 Austria 

 Bahrain 

 Belgium 

 Brazil 

 Bulgaria 

 Canada 

 Chile 

 China, PRC 

 Colombia 

 Costa Rica 

 Croatia 

 Cyprus 

 Czech Republic 

Denmark 

 Ecuador 

 Egypt 

 El Salvador 

 Finland 

 France 

 Germany 

 Greece 

 Guatemala 

 Honduras 

 Hong Kong 

 Hungary 

 Iceland 

 India 

 Indonesia 

 

Ireland 

Israel 

 Italy 

 Jamaica 

 Japan 

 Jordan 

 Korea 

 Kuwait 

 Lebanon 

 Malaysia 

 Mexico 

 Netherlands 

New Zealand 

 Norway 

 Pakistan 

 Peru 

Philippines 

 Poland 

 Portugal 

 Puerto Rico 

 Qatar 

 Romania 

 Russia-CIS 

 Saudi Arabia 

 Singapore 

 Slovakia 

 Slovenia 

 South Africa, Republic 

 Spain 

Sweden 

Switzerland 

 Taiwan 

 Thailand 

 Turkey 

 United Arab Emirates 

 United Kingdom 

 United States 

 Uruguay 

 Venezuela 

 Yugoslavia

AllenBradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 3822000 Fax: (1) 414 3824444

Publication 17715.37 - October 1995

PN955123-94

Copyright 1995 AllenBradley Company, Inc.   Printed in USA

Summary of Contents for 1771-OWN

Page 1: ...ate loads with a maximum of 12A per module Each output can conduct a maximum load of 1 0A continuously at 30W maximum Ac loads switched by the modules should have a power factor PF of 1 0 Maximum interconnect cable length for this module is 1000 ft 304 8 meters European Union Directive Compliance If this product is installed within the European Union or EEA regions and has the CE mark the followin...

Page 2: ...ll coils are energized is 2 5A Nominal backplane current is 1 8A When handling the module observe the following warning ATTENTION Remove power from the 1771 I O chassis backplane and field wiring arm before removing or installing an I O module Failure to remove power from the backplane or wir ing arm could cause module damage degradation of performance or injury Failure to remove power from the ba...

Page 3: ...es Setting the Relay Output Jumpers When the output image table bit at the address corresponding to any output is energized set to 1 the corresponding relay contact is closed or opened respective to the jumper setting All outputs are individually selectable for either normally open or normally closed operation They are pre set for normally open operation at the factory To reset any jumper proceed ...

Page 4: ...ot used 11 Common 1 31 Common 3 12 Output 10 L 10 32 Output 10 H 10 13 Output 11 L 11 33 Output 11 H 11 14 Output 12 L 12 34 Output 12 H 12 15 Output 13 L 13 35 Output 13 H 13 16 Output 14 L 14 36 Output 14 H 14 17 Output 15 L 15 37 Output 15 H 15 18 Output 16 L 16 38 Output 16 H 16 19 Output 17 L 17 39 Output 17 H 17 20 Not used 40 Not used Inserting the Module Into the Chassis 1 Turn off power t...

Page 5: ...iagram Use the label on the front of the wiring arm to identify your wiring ATTENTION The field wiring arm terminal identification number is not the same as the number of the bit which controls that output Connection Diagram for the 1771 OWN Module Output 0 Output 2 Output 4 Output 6 Not used Output 10 Output 12 Output 14 Output 16 Not used Output 0 Output 2 Output 4 Output 6 Not used Output 10 Ou...

Page 6: ...he output module are not isolated from each other Driving an Input Module with a 1771 OWN Output Module 120V AC Input Module Cat No 1771 IAD Selectable Contact Output Module Cat No 1771 OWN ac High ac Low L1 L2 Input 00 Input 01 Input 02 Input 03 Input 04 Input 05 Input 06 Input 07 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 Input 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 ...

Page 7: ... the module front plate These represent the control status of the output relays Each indicator is lit when its corresponding relay is energized 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 Status Indicators red 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 10541 I Interpreting the Status Indicators Allen Bradley Spares ...

Page 8: ...or all applicable directives 1 Spikes peaks and surges must be within the power rating Resistive loads only ac and dc power 30W max 2 Surge limiting circuitry is not provided in the module For reliable operation the user must ensure that surges do not exceed either the voltage or current rating of the module 3 You use this conductor category information for planning conductor routing as described ...

Reviews: