Wiring the Home Limit Switch Input
The home limit switch inputs to the servo module are designed for 24V dc
nominal operation. These inputs should be wired for current sourcing
operation.
Figure 9 Home Limit Switch Input
Wiring the OK Contacts
A set of isolated solid- state OK relay contacts is provided for optional
interface to an E- stop string, which controls power to the associated pumps.
The OK contacts are rated to drive an external 24V dc pilot relay (for
example, Allen-Bradley 700- HA32Z24) whose contacts can be incorporated
into the E- Stop string as in the following figure.
Figure 10 Wiring OK Contacts