Allen-Bradley 1732E-16CFGM12P5QCR User Information Download Page 4

4

    1732E ArmorBlock 2-Port EtherNet/IP Modules with QuickConnect 

Publication 1732E-IN010C-EN-E - June 2013

Additional Resources

If you would like a manual, you can:

download a free electronic version from the internet: 

http://www.rockwellautomation.com/literature/

purchase a printed manual by contacting your local Allen-Bradley distributor or 
Rockwell Automation representative

Overview

The 1732E-12X4M12QCDR, 1732E-12X4M12P5QCDR, 1732E-16CFGM12QCR, 
1732E-16CFGM12P5QCR, 1732E-16CFGM12QCWR, 
1732E-16CFGM12P5QCWR ArmorBlock

 are I/O modules that communicate via 

EtherNet/IP. The sealed IP65, IP66, IP67 and IP69K housing of these modules requires 
no enclosure. The I/O modules have dual Ethernet ports and use an embedded Ethernet 
switch.

The modules have Auxiliary power In and Out connectors. There is no need to house 
these modules in a secondary enclosure. The I/O modules support the QuickConnect 
feature, onboard nonvolatile memory for storing block-specific data such as Tool ID and 
counter value, and provide basic distributed I/O functionality. 

Resource

Description

ArmorBlock 2-Port EtherNet with Diagnostics 
and QuickConnect Wiring Diagrams, 
publication 

1732E-WD004

Detailed description of how to wire your 
1732E-12X4M12QCDR or 1732E-12X4M12P5QCDR 
module.

ArmorBlock WeldBlock 2-Port Ethernet 
Self-configurable with QuickConnect Wiring 
Diagrams, publication 

1732E-WD005

Detailed description of how to wire your 
1732E-16CFGM12QCWR  or 
1732E-16CFGM12P5QCWR module.

ArmorBlock 2-Port Ethernet Self-configurable 
with QuickConnect Wiring Diagrams, 
publication 

1732E-WD006

Detailed description of how to wire your 
1732E-16CFGM12QCR or 
1732E-16CFGM12P5QCR module.

Ethernet QuickConnect Application 
Technique, publication 

ENET-AT001

Detailed explanation on how to set up and use 
QuickConnect ArmorBlock modules.

Industrial Automation Wiring and Grounding 
Guidelines, publication 

1770-4.1

More information on proper wiring and grounding 
techniques.

Summary of Contents for 1732E-16CFGM12P5QCR

Page 1: ...732E 16CFGM12P5QCWR Table of Contents Topic Page Important User Information 2 Environment and Enclosure 3 Preventing Electrostatic Discharge 3 Overview 4 Catalog Number Explanation 5 Install the Modul...

Page 2: ...particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc wi...

Page 3: ...bsequent sections of this publication may contain additional information regarding specific enclosure type ratings beyond what this product provides that are required to comply with certain product sa...

Page 4: ...pport the QuickConnect feature onboard nonvolatile memory for storing block specific data such as Tool ID and counter value and provide basic distributed I O functionality Resource Description ArmorBl...

Page 5: ...twork Connector Auxiliary Power 1732E 12X4M12QCDR Diagnostic 12 input 4 output 24V DC digital I O dual port Ethernet module with QuickConnect Dual D code M12 Dual 4 pin mini 1732E 12X4M12P5QCDR Diagno...

Page 6: ...st to determine if the switches are set to a valid number To set the network address 1 Rotate the three 3 switches on the front of the module using a small blade screwdriver 2 Line up the small notch...

Page 7: ...d number for example 000 or a value greater than 254 excluding 888 the I O block checks to see if DHCP is enabled If DHCP is enabled the I O block asks for an address from a DHCP server The DHCP serve...

Page 8: ...e in an area that is subject to shock or vibration we recommend you use a flat and a lock washer to mount the module Mount the flat and the lock washer as shown in the mounting illustration Torque the...

Page 9: ...connect cord sets you selected for your module to the appropriate ports I O Connectors Micro style 5 Pin Input Female Connector ATTENTION To comply with the CE Low Voltage Directive LVD this equipment...

Page 10: ...e output is on If an I O point is to be an input wire the input device as normal and leave the associated output de energized at all times Micro style 5 Pin Selectable Point Connector ATTENTION Make s...

Page 11: ...585D M4DC H Polyamide small body unshielded or the 1585D M4DC SH Zinc die cast large body shielded mating connectors for the D Code M12 female network connector 43601 View into connector 1 Pin 1 M12_T...

Page 12: ...r cycled QuickConnect is active during the next connection Once active the QuickConnect feature automatically sets all Ethernet ports to Speed 100 Mbps Duplex Full Auto negotiate Off Automatic Cross o...

Page 13: ...ceptacle as shown below Mini style 5 Pin Receptacle TIP The ground for both module power and output power are shared ATTENTION This equipment is considered Group 1 Class A industrial equipment accordi...

Page 14: ...on the devices used it may be possible to provide power through only one pair of the four available pins and in this case the other available pair may be used for single channel E stop through the use...

Page 15: ...write to the module memory To read from the module 1 Send an EtherNet IP Explicit Message with the following information To write to the module 2 Send the following three EtherNet IP Explicit Messages...

Page 16: ...or inputs and outputs Stop command Service Code 07 hex Class ID 6E hex Instance ID 1 Attribute ID 1 LINK 1 LINK 2 MOD NET LINK 1 LINK 2 MOD NET PORT 1 PORT 2 AUX POWER AUX POWER PORT 1 PORT 2 45762 17...

Page 17: ...shing red Recoverable fault Red Unrecoverable fault may require device replacement LINK 1 LINK 2 MOD NET LINK 1 LINK 2 MOD NET PORT 1 PORT 2 AUX POWER AUX POWER PORT 1 PORT 2 46201 1732E 16CFGM12P5QCR...

Page 18: ...tivity present on indicated port at 100 Mbps Yellow Link established on indicated port at 10 Mbps Flashing yellow Link activity present on indicated port at 10 Mbps Power status Off No power to device...

Page 19: ...input min 12V DC Current off state input max 1 5 mA 5V DC Current on state input max 5 mA 30V DC Voltage sensor source max 30V DC Voltage sensor source min 10V DC Input delay time ON to OFF OFF to ON...

Page 20: ...for output loads 2 A 1732E 12X4M12QCDR 1732E 12X4M12P5QCDR 8 A all other modules Current auxiliary power connector max per module 10 A Current sensor source per input max 50 mA Current sensor source...

Page 21: ...perature operating IEC 60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock 20 60 C 4 140 F Temperature ambient max 60 C 140 F Tempe...

Page 22: ...ne wave 80 AM from 150 kHz 80 MHz Certifications Certification when product is marked 1 1 See the Product Certification link at http www ab com for Declaration of Conformity Certificates and other cer...

Page 23: ...1732E ArmorBlock 2 Port EtherNet IP Modules with QuickConnect 23 Publication 1732E IN010C EN E June 2013 Notes...

Page 24: ...e fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures Documentation Feedback Your comments will h...

Reviews: