background image

XONE VF-1 

RIAA Option Fitting Instructions   

 

 

         

 

 

         1 

 
 
 
 
 
 

An RIAA pre-amplifier compensates for the characteristics of vinyl reproduction by attenuating the high 

and boosting the low frequencies, according to the standard slope specified by the Recording Industry of 
America. 

 

The XONE VF-1 is available with a factory-fitted RIAA preamp option to allow a high quality magnetic 
cartridge turntable to be used as an input to the unit.  

This option is only available on units fitted with 

an issue 4 (or later) main PCB.

  The issue number is printed on the PCB, and can be checked by 

looking through the ventilation slots on top of the unit, without the need to remove the cover. 

 

Retro-fitment of the RIAA option is possible – this involves removing the unit’s cover.  Due to the mains 
voltages present within the unit, this is not considered a task for the end user.  These instructions are 
provided for reference – 

any work on the internal parts of the unit should be carried out by 

technically competent personnel.

 

For information on how to use the 

XONE VF-1

 please refer to User Guide AP5917.  Should further 

assistance be required, please contact Allen & Heath Technical Support (details on our web site 
www.allen-heath.com). 

Before Starting     

Read these fitting instructions carefully before starting.  For trouble free installation and operation heed all 
the precautions noted.  The unit must be fully unplugged and removed from its rack, plinth or other 
furniture before carrying out the work.  Normal workshop tools are required, including a Torx (starhead) 
T10 screwdriver.  Provide a suitably large, well lit work surface such as a service workshop bench.  To 
avoid damage to the cosmetics of the unit ensure that the work surface is clean and clear of obstructions.  

Allow enough time to carry out the work properly and test the results. 

Required Components 

The following parts are required: 

003-360 x1   RIAA Option circuit assembly  

AB3704 x1  Brass pillar, M3x12 

 

 
 
IMPORTANT

:

   Any changes or modifications 

to the equipment not approved by Allen & Heath 
could void the compliance of the equipment.  
Whilst we believe the information in these 
instructions to be reliable we do not assume 
responsibility for inaccuracies. We also reserve 

the right to make changes in the interest of 
further product development. 

Copyright© 2004 Allen & Heath Limited. All rights 
reserved.         www.allen-heath.com 

 
 

 

This work should be carried out only by 

qualified technical personnel authorised by 
Allen & Heath. 

 

Disconnect the mains power cord before 

opening the unit. 

 

Take care not to damage the panels or 

internal assemblies during fitting.  Prevent 
loose parts or dirt from entering the unit as 
this may cause equipment failure. 

Fitting Instructions 

Step 1:  

Preparation 

Ensure the console is powered off.  Disconnect the mains power lead and all connected cables.  Remove 
the console from its rack or other furniture and place on the work surface. 

ALLEN

&

HEATH               

  

RIAA Option

 

Fitting Instructions for the XONE VF-1 RIAA Option

 

1

FH1

CN1

FEMALE

1

R20

R19

R18

C1

C2

C4

C6

C7

C8

C9

C10

C11

C12

C13

C14

FH1

R1

R2

R3

R4

R5

R6

R7

R8

R9

R10

R11

R12

R13

R14

R15

R16

U1

U2