20
ML3000
Service Manual
Internal Options Links
The
ML3000
is designed to offer the utmost flexibility to satisfy the application without modification.
However, the following internal link options are provided to allow customisation to satisfy the more
specialist applications or personal preferences. Remember to set these internal links according to
the user requirement if replacing assemblies while carrying out service work:
Mono channel AUX options
The pre-fade sends are set pre-insert, pre-EQ, post-mute
as standard. Jumper links on the mono circuit cards can be replugged to configure
post-insert, pre or post-EQ and/or pre-mute. Refer to drawing
D1 and D2.
Stereo channel AUX options
The pre-fade sends are set pre-EQ, post-mute as
standard. Jumper links on the stereo circuit cards can be replugged to configure post-
EQ and/or pre-mute. Refer to drawing D4 and D6.
Mono channel DIRECT outputs
These are derived post channel fader as standard. A
jumper link on each card can be replugged to configure pre-fader or post-fade with level
trim. The direct out pre-fade source is the same as that configured to feed the aux
sends. The level trim option disables the channel Aux1 send and uses its send as the
direct out level control. Two links need to be set in this case, one to send the direct
output signal through the send control, the other to disable the Aux1 send from the
channel. Refer to drawing D1.
2-track output source
These are set post master insert and fader as standard. Two
pairs of jumper links can be replugged to derive the output pre-insert, pre-fader. Refer
to drawing D27 and D28.
Internal Assembly Assignments
The following assignment links need to be set according to assembly position in the console.
These should not need changing unless a replacement assembly has been fitted.
Group / Aux buss assignment
Zero ohm links determine which busses feed the
group and aux mix amps. Refer to drawings D11, D12 and D13.
Aux Matrix buss assignment
Zero ohm links determine which busses feed the aux
mix amps. Refer to drawing D14 and D15.
VU meters 1-8
The same assembly type is used for meters 1-4 and 5-8. The position
in the console is determined by soldered links. Refer to drawings D48, D49 and D50.
CPU assignment
Position the three links according to the console type as shown on
drawing D23
Summary of Contents for ML 3000
Page 1: ...SERVICE MANUAL Publication AP4511 Dual Function Live Sound Console ...
Page 33: ......
Page 34: ......
Page 37: ......
Page 41: ......
Page 44: ......
Page 47: ......
Page 50: ......
Page 52: ......
Page 54: ......
Page 56: ......
Page 60: ......
Page 63: ......
Page 67: ......
Page 71: ......
Page 74: ......
Page 76: ......
Page 78: ......
Page 81: ......
Page 84: ......