ALLEN & HEATH DR66 Fitting Instructions Download Page 2

DR66 SysNet

 Fitting Instructions 

AP3168 issue 4 

 

 

Fitting Procedure 

 

Step 1 

Check which version of PIC you need.  The V4 part is 
fitted as standard.  If you need to run the earlier V2 
version then carefully unplug the 28-pin integrated 
circuit and replace it with the V2 version supplied.  
Make sure  its pin 1 is positioned as shown and the pins 
are correctly aligned and pressed in. 

 

 

Step 2 

Turn off power to the DR66 and unplug the mains 
cable.  Remove the 7 fixing screws as shown and lift off 
the top cover.  Do not remove the power unit safety 
cover. 

 

 

Step 3 

Remove the rear panel SysNet option slot blanking 
plate by unscrewing the two fixing screws. 

Locate and carefully unplug the 26way harness that 
connects between the CPU and Connector circuits. 

 

 

Step 4 

Fit the snap-in mounting pillars to the track side of the 
SysNet card and mount the assembly into the DR66 
rear panel using the two fixings attached to the D-type 
connector. 

Fold and position the new 26way harness as shown 
plugging it into the CPU, Connector and SysNet cards.  
Note the position of the pin 1 red stripe. 

Make sure the harness pins are correctly aligned with 
the mating connector pins.  Push the plugs fully home. 

 

 

Step 5 

Check your work and refit the top cover.  Power up the 
DR66 and check that it boots up correctly. 

 

Refer to the relevant SysNet Protocol document for 
details on programming the remote controller.  For 
instructions on programming and operating the remote 
controller refer to the supplier of that equipment. 

 

For the latest information on the DR Series visit the 
Allen & Heath web site.  For further technical support  
or comment on using this equipment please contact or 
email [email protected]

 