background image

© Allegion 2019

47267374 Rev. 03/19-a

Customer Service

For details regarding the limited warranty:

1-877-671-7011

www.allegion.com/us

NC450 series of electric strikes are designed for use with cylindrical locksets and accommodate latchbolts up to 9/16" throw. The

strikes can be configured to fail-safe or fail-secure on site.

Specifications

Electric Strike Installation Instructions

NC450 Series

12VDC or 24VDC 

70 ft-lbs

Operating Voltage

Operating Temperature

Strike Humidity

Current Draw

Dynamic Strength

Latch Throw

Keeper Width

9/16" (15mm) maximum

1 7/16" (36mm)

(voltage non-polarized)
± 10% 

Voltage Tolerance

0% to 85% Non-condensing

For indoor use: 14°F to 120°F (-10°C to + 49°C)

Dual Voltage:

300mA/12VDC, 150mA/24VDC

250,000 cycles

Endurance Test

1500 lbs (680Kg)

Static Strength

Latch Monitor

(when applicable)

Keeper

Strike Body 

6 7/8″ NCCFP-KIT

(US32D, US10B)

7 15/16″ NCWFP-KIT

(US32D, US10B)

Included in box:

(Square and Radius)

Optional Faceplates:

Faceplate

Model

Latch

Body

Latch

Zinc Alloy

9/16″

(15mm)

NC450
NC450-LBM

Construction

Monitor

Throw

Black

Black

Dual Voltage (Non-polarized)

Red

White

Green

White

White

24 VDC

Green

Black

Red

Red

Red

(Non-polarized)

Red & Black: 12VDC

White & Red: 24 VDC

Overheated or burnt coils caused by incorrect voltage/wire 

harness combinations will not be covered under warranty

 CAUTION

Wiring Diagrams

6 7/8” (174.6mm)

3 3/8” (85mm)

1 7/16” (36mm)

(31.75mm)

4 7/8” (123.8mm)

3 3/8” (85mm)

1 7/16” (36mm)

1 1/4

” 

(31.75mm)

7 15/16” (201.6mm)

3 3/8” (85mm)

1 7/16” (36mm)

(36.5mm)

1 7/16”

 

1 1/16” (27mm)

1 1/4

” 

 1 3/8” (35mm)

Reviews: